Call Us Today: (800) 462-7733
Digital monitoring relay 3-phase supply voltage autom. phase sequence correction phase failure 3 x 160 to 690 v 50 to 60 HZ AC undervoltage and overvoltage 160-690 v hysteresis 1-20 v off delay 0-20 s asymmetry 0-20% 1 co for phase correction 1 co for line supply faults spring-type connection system
Digital monitoring relay 3-phase supply voltage autom. phase sequence correction phase failure 3 x 160 to 690 v 50 to 60 HZ AC undervoltage and overvoltage 160-690 v hysteresis 1-20 v off delay 0-20 s asymmetry 0-20% 1 co for phase correction 1 co for line supply faults spring-type connection system

Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more information.

$457.50 / EA

manufacturer discounts
learn about discounts

  • $410.18 for $1,500.00+
  • $394.40 for $2,500.00+
  • $378.62 for $3,500.00+

In stock (0)
Lead time: over 7 days
may be longer on small orders

Digital monitoring relay 3-phase supply voltage autom. phase sequence correction phase failure 3 x 160 to 690 v 50 to 60 HZ AC undervoltage and overvoltage 160-690 v hysteresis 1-20 v off delay 0-20 s asymmetry 0-20% 1 co for phase correction 1 co for line supply faults spring-type connection system

Digital monitoring relay 3-phase supply voltage autom. phase sequence correction phase failure 3 x 160 to 690 v 50 to 60 HZ AC undervoltage and overvoltage 160-690 v hysteresis 1-20 v off delay 0-20 s asymmetry 0-20% 1 co for phase correction 1 co for line supply faults spring-type connection system

150

UPC
754554937205
UNSPSC
39122334
Country of Origin
DE
Accuracy of digital display:
+/-1digit
Adjustable response delay time / with lower or upper limit violation / Full-scale value:
20 s
Ambient temperature / during operation / maximum:
60 °C
Ambient temperature / during operation / minimum:
-25 °C
Control supply voltage / at AC / at 50 Hz / Rated value / maximum:
690.0 V
Control supply voltage / at AC / at 50 Hz / Rated value / minimum:
160.0 V
Control supply voltage / at AC / at 60 Hz / Rated value / maximum:
690.0 V
Control supply voltage / at AC / at 60 Hz / Rated value / minimum:
160.0 V
Relative metering precision:
5 %
Type of electrical connection:
spring-loadedterminals
Compare With Similar Items
Data Concentration Access Point - Extended Range 902-928MHz Wireless 1000 Meter Points 5VDC, 1A (120VAC Power Supply Included) Packed 1/Bulk.

T25DX-102

$4,267.25 /ea

Data Concentration Access Point - Extended Range 902-928MHz Wireless 1000 Meter Points 5VDC, 1A (120VAC Power Supply Included) Packed 1/Bulk.

Data Concentration Access Point - Extended Range 902-928MHz Wireless 2000 Meter Points 5VDC, 1A (120VAC Power Supply Included) Packed 1/Bulk.

T25DX-202

$6,281.86 /ea

Data Concentration Access Point - Extended Range 902-928MHz Wireless 2000 Meter Points 5VDC, 1A (120VAC Power Supply Included) Packed 1/Bulk.

The HD Pulse Module is perfect for bringing large banks of pulse submeters into Modbus networks. Connect up to 23 dry contact pulse outputs for easy Modbus RS-485 integration

A8911-23

$582.23 /ea

The HD Pulse Module is perfect for bringing large banks of pulse submeters into Modbus networks. Connect up to 23 dry contact pulse outputs for easy Modbus RS-485 integration

Attributed Data Included
Class A Yes
Communication Modbus/RTU Yes
Environmental Conditions Relative Humidity (0 to 95% Non-Condensing) Yes
Number Of Relays 2 Yes
Processor ARM7 field upgradeable firmware Yes
Standard FCC CFR (47 Part 15) Yes
Type High Density Pulse Module Yes
Must be purchased in multiples of 10
See more details

Recently Viewed

  • placeholder image

    HOM120CAFI

    SQUARE D
    SQUARE D 1POLE 20A ARC FAULT (EACH)
    See more details
  • placeholder image

    6XV18402AN50

    SIEMENS INDUSTRY, INC.
    IE FC TP STANDARD CABLE GP 2X2 (PROFINET TYPE A). CAT5E. BUS CABLE 4-WIRE. SHIELDED. SPEC. DESIGN FOR RAPID INSTALL. TO IE FC RJ45 PLUG 2X2. 50 M
    See more details
  • placeholder image

    P710050-015-30

    PROGRESS LIGHTING
    Parallel LED vanity and sconces feature a tubular opal glass diffuser paired with a simple, modern metal canopy. An integrated LED source provides a v...
    See more details
  • placeholder image

    50658-GRNL

    GREENLEE TEXTRON
    PIN,COTTER (.187 X 1.50) (90506588)
    See more details
  • placeholder image

    3UG46172CR20

    SIEMENS INDUSTRY, INC.
    Digital monitoring relay 3-phase supply voltage autom. phase sequence correction phase failure 3 x 160 to 690 v 50 to 60 HZ AC undervoltage and overvo...
    See more details

ADDED TO CART