Call Us Today: (800) 462-7733
DIGITAL MONITORING RELAY FOR FAULT CURRENT MONITORING (W. CURRENT TRANSFORMER 3UL23) SETTING RANGE 0.03A TO 40A SEPARATE FOR ALARM THRESHOLD AND SWITCH-OFF VALUE SUPPLY VOLTAGE AC/DC 24 .. 240 V, 50 .. 60 HZ STARTUP AND TRIPPING DELAY 0.1 TO 20S SWITCH-OFF HYSTERESIS UP TO 50% ALARM HYSTERESIS 5% FIXED WIDTH 22.5 MM, 2 CO CONTACTS W. OR W/O ERROR LOG SPRING-LOADED TERMINAL
DIGITAL MONITORING RELAY FOR FAULT CURRENT MONITORING (W. CURRENT TRANSFORMER 3UL23) SETTING RANGE 0.03A TO 40A SEPARATE FOR ALARM THRESHOLD AND SWITCH-OFF VALUE SUPPLY VOLTAGE AC/DC 24 .. 240 V, 50 .. 60 HZ STARTUP AND TRIPPING DELAY 0.1 TO 20S SWITCH-OFF HYSTERESIS UP TO 50% ALARM HYSTERESIS 5% FIXED WIDTH 22.5 MM, 2 CO CONTACTS W. OR W/O ERROR LOG SPRING-LOADED TERMINAL

Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more information.

$326.58 / EA

manufacturer discounts
learn about discounts

  • $292.80 for $1,500.00+
  • $281.54 for $2,500.00+
  • $270.28 for $3,500.00+

In stock (0)
Lead time: over 7 days
may be longer on small orders

DIGITAL MONITORING RELAY FOR FAULT CURRENT MONITORING (W. CURRENT TRANSFORMER 3UL23) SETTING RANGE 0.03A TO 40A SEPARATE FOR ALARM THRESHOLD AND SWITCH-OFF VALUE SUPPLY VOLTAGE AC/DC 24 .. 240 V, 50 .. 60 HZ STARTUP AND TRIPPING DELAY 0.1 TO 20S SWITCH-OFF HYSTERESIS UP TO 50% ALARM HYSTERESIS 5% FIXED WIDTH 22.5 MM, 2 CO CONTACTS W. OR W/O ERROR LOG SPRING-LOADED TERMINAL

DIGITAL MONITORING RELAY FOR FAULT CURRENT MONITORING (W. CURRENT TRANSFORMER 3UL23) SETTING RANGE 0.03A TO 40A SEPARATE FOR ALARM THRESHOLD AND SWITCH-OFF VALUE SUPPLY VOLTAGE AC/DC 24 .. 240 V, 50 .. 60 HZ STARTUP AND TRIPPING DELAY 0.1 TO 20S SWITCH-OFF HYSTERESIS UP TO 50% ALARM HYSTERESIS 5% FIXED WIDTH 22.5 MM, 2 CO CONTACTS W. OR W/O ERROR LOG SPRING-LOADED TERMINAL

150

UPC
804766187476
UNSPSC
39121106
Country of Origin
DE
Ambient temperature / during operation / maximum:
60 °C
Ambient temperature / during operation / minimum:
-25 °C
Ambient temperature / during storage / maximum:
85 °C
Ambient temperature / during storage / minimum:
-40 °C
Ampacity / of the output relay / at DC-13 / at 24 V:
1 A
Buffering time / in the event of power failure / minimum:
10 ms
Continuous current / of the DIAZED fuse link of the output relay:
4 A
Operating frequency / rated value / maximum:
400 Hz
Operating frequency / rated value / minimum:
16 Hz
Compare With Similar Items
SITOP CNX8600 4X 10A EXTENSION MODULE FOR PSU8600 OUTPUT 24 V/4X 10 A DC VERSION BMW

6EP44378XB000CP0

$489.96 /ea

SITOP CNX8600 4X 10A EXTENSION MODULE FOR PSU8600 OUTPUT 24 V/4X 10 A DC VERSION BMW

SITOP CNX8600 4X 5A EXTENSION MODULE FOR PSU8600 OUTPUT 24 V/4X 5 A DC VERSION BMW

6EP44368XB000CP0

$445.01 /ea

SITOP CNX8600 4X 5A EXTENSION MODULE FOR PSU8600 OUTPUT 24 V/4X 5 A DC VERSION BMW

SITOP CNX8600 4X 5A EXTENSION MODULE FOR PSU8600 OUTPUT 24 V/4X 5 A DC

6EP4436-8XB00-0CY0

$422.53 /ea

SITOP CNX8600 4X 5A EXTENSION MODULE FOR PSU8600 OUTPUT 24 V/4X 5 A DC

ADDED TO CART