Call Us Today: (800) 462-7733
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA62 FRAME WITH MEDIUM HIGH (CLASS C) BREAKING CAPACITY. 100A 4-POLE (35KAICAT 600V) (100KAIC AT 480V). ETU550 TRIP UNIT LCD LSI. SPECIAL FEATURES WITHOUT LUGS.. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.

Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more information.

3VA6210-7JP41-0AA0

$6,163.78 / EA

manufacturer discounts
learn about discounts

  • $5,526.14 for $1,500.00+
  • $5,313.60 for $2,500.00+
  • $5,101.06 for $3,500.00+

In stock (0)
Lead time: over 7 days
may be longer on small orders

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA62 FRAME WITH MEDIUM HIGH (CLASS C) BREAKING CAPACITY. 100A 4-POLE (35KAICAT 600V) (100KAIC AT 480V). ETU550 TRIP UNIT LCD LSI. SPECIAL FEATURES WITHOUT LUGS.. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA62 FRAME WITH MEDIUM HIGH (CLASS C) BREAKING CAPACITY. 100A 4-POLE (35KAICAT 600V) (100KAIC AT 480V). ETU550 TRIP UNIT LCD LSI. SPECIAL FEATURES WITHOUT LUGS.. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.

150

UPC
804766310805
UNSPSC
39121601
Country of Origin
CZ
Number Of Poles:
4
Type:
3VA6
Voltage Rating:
480 V
Adjustable delay time / of S-trip / with I2t characteristic / Full-scale value:
0.50s
Adjustable delay time / of S-trip / with I2t characteristic / initial value:
0.05s
Adjustable delay time / of S-trip / with standard characteristic / Full-scale value:
0.50s
Ambient temperature / during operation / maximum:
70
Ambient temperature / during operation / minimum:
-25
Ambient temperature / during storage / maximum:
80
Arrangement of electrical connectors / for main current circuit:
Withoutconnection
Connection:
punched copper bar without any lug
Current Rating:
100 A
Electrical endurance (switching cycles) / at AC-1 / at 380/415 V / at 50/60 Hz:
6000
Electrical endurance (switching cycles) / at AC-1 / at 690 V / at 50/60 Hz:
3000
Frame:
250A
Height:
198
Interrupt Rating:
WITH 100kA INTERRUPTION RATING
Length:
5.51
Mechanical service life (switching cycles) / typical:
20000
Mounting type:
fixedmounting
Number Of Poles:
4
Product variations:
Advancedapplications
Protection class IP:
IP40
Protection class IP / on the front:
IP40
Reference code / acc. to DIN EN 61346-2:
Q
Reference code / acc. to DIN EN 81346-2:
Q
Setting range / Overload function L / IR can be switched on:
No
Short-circuit current making capacity (Icm) / at 240 V / rated value:
330kA
Short-circuit current making capacity (Icm) / at 415 V / rated value:
242kA
Standard:
UL
Sub Brand:
3VA
Trip Type:
ETU550 LSI LCD
Type:
3VA6
Type of electrical connection / for main current circuit:
Without
Voltage Rating:
480 V
Width:
140
Compare With Similar Items
Enclosed Circuit Breaker, Type Bolted Enclosure, Constructional Feature Explosionproof, Dust-Ignitionproof, Breaker Type FDB, Trip Type Thermal Magnetic, Voltage Rating 600 VAC/250 VDC, Current Rating 100 Ampere, Number of Poles 2, Hub Location Feed...

EB2F2W100

$3,551.46 /ea

Enclosed Circuit Breaker, Type Bolted Enclosure, Constructional Feature Explosionproof, Dust-Ignitionproof, Breaker Type FDB, Trip Type Thermal Magnetic, Voltage Rating 600 VAC/250 VDC, Current Rating 100 Ampere, Number of Poles 2, Hub Location Feed Through, Enclosure NEMA 3R/7B/7C/7D/9E/9F/9G, Enclosure Material Copper-Free Aluminum, Enclosure Finish 2 Coat Epoxy Enamel, Shaft/Handle Material Stainless Steel, Mounting Surface, Approval UL 1203, Applications Corrosive Atmosphere, Hazardous Location, Refinery, Chemical Plants, Petrochemical Plants, Processing Plants, Shaft/Bushing Material Stainless Steel

Enclosed Circuit Breaker, Type Bolted Enclosure, Constructional Feature Explosionproof, Dust-Ignitionproof, Breaker Type FDB, Trip Type Thermal Magnetic, Voltage Rating 600 VAC/250 VDC, Current Rating 125 Ampere, Number of Poles 2, Hub Location Feed...

EB2F2W125

$5,172.97 /ea

Enclosed Circuit Breaker, Type Bolted Enclosure, Constructional Feature Explosionproof, Dust-Ignitionproof, Breaker Type FDB, Trip Type Thermal Magnetic, Voltage Rating 600 VAC/250 VDC, Current Rating 125 Ampere, Number of Poles 2, Hub Location Feed Through, Enclosure NEMA 3R/7B/7C/7D/9E/9F/9G, Enclosure Material Copper-Free Aluminum, Enclosure Finish 2 Coat Epoxy Enamel, Shaft/Handle Material Stainless Steel, Mounting Surface, Approval UL 1203, Applications Corrosive Atmosphere, Hazardous Location, Refinery, Chemical Plants, Petrochemical Plants, Processing Plants, Shaft/Bushing Material Stainless Steel

Enclosed Circuit Breaker, Type Bolted Enclosure, Constructional Feature Explosionproof, Dust-Ignitionproof, Breaker Type FDB, Trip Type Thermal Magnetic, Voltage Rating 600 VAC/250 VDC, Current Rating 150 Ampere, Number of Poles 2, Hub Location Feed...

EB2F2W150

$5,172.97 /ea

Enclosed Circuit Breaker, Type Bolted Enclosure, Constructional Feature Explosionproof, Dust-Ignitionproof, Breaker Type FDB, Trip Type Thermal Magnetic, Voltage Rating 600 VAC/250 VDC, Current Rating 150 Ampere, Number of Poles 2, Hub Location Feed Through, Enclosure NEMA 3R/7B/7C/7D/9E/9F/9G, Enclosure Material Copper-Free Aluminum, Enclosure Finish 2 Coat Epoxy Enamel, Shaft/Handle Material Stainless Steel, Mounting Surface, Approval UL 1203, Applications Corrosive Atmosphere, Hazardous Location, Refinery, Chemical Plants, Petrochemical Plants, Processing Plants, Shaft/Bushing Material Stainless Steel

ADDED TO CART