![SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA62 FRAME WITH MEDIUM HIGH (CLASS C) BREAKING CAPACITY. 100A 4-POLE (35KAICAT 600V) (100KAIC AT 480V). ETU550 TRIP UNIT LCD LSI. SPECIAL FEATURES WITHOUT LUGS.. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.](https://www.ideadigitalcontent.com/files/10991/ID-PIC-v1-3VA62xxxJP410.png)
Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more
information.
$6,163.78 / EA
manufacturer discounts
learn about discounts
- $5,526.14 for $1,500.00+
- $5,313.60 for $2,500.00+
- $5,101.06 for $3,500.00+
In stock (0)
Lead time: over 7 days
may be longer on small orders
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA62 FRAME WITH MEDIUM HIGH (CLASS C) BREAKING CAPACITY. 100A 4-POLE (35KAICAT 600V) (100KAIC AT 480V). ETU550 TRIP UNIT LCD LSI. SPECIAL FEATURES WITHOUT LUGS.. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA62 FRAME WITH MEDIUM HIGH (CLASS C) BREAKING CAPACITY. 100A 4-POLE (35KAICAT 600V) (100KAIC AT 480V). ETU550 TRIP UNIT LCD LSI. SPECIAL FEATURES WITHOUT LUGS.. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.
150
- UPC
- 804766310805
- UNSPSC
- 39121601
- Country of Origin
- CZ
- Number Of Poles:
- 4
- Type:
- 3VA6
- Voltage Rating:
- 480 V
- Adjustable delay time / of S-trip / with I2t characteristic / Full-scale value:
- 0.50s
- Adjustable delay time / of S-trip / with I2t characteristic / initial value:
- 0.05s
- Adjustable delay time / of S-trip / with standard characteristic / Full-scale value:
- 0.50s
- Ambient temperature / during operation / maximum:
- 70
- Ambient temperature / during operation / minimum:
- -25
- Ambient temperature / during storage / maximum:
- 80
- Arrangement of electrical connectors / for main current circuit:
- Withoutconnection
- Connection:
- punched copper bar without any lug
- Current Rating:
- 100 A
- Electrical endurance (switching cycles) / at AC-1 / at 380/415 V / at 50/60 Hz:
- 6000
- Electrical endurance (switching cycles) / at AC-1 / at 690 V / at 50/60 Hz:
- 3000
- Frame:
- 250A
- Height:
- 198
- Interrupt Rating:
- WITH 100kA INTERRUPTION RATING
- Length:
- 5.51
- Mechanical service life (switching cycles) / typical:
- 20000
- Mounting type:
- fixedmounting
- Number Of Poles:
- 4
- Product variations:
- Advancedapplications
- Protection class IP:
- IP40
- Protection class IP / on the front:
- IP40
- Reference code / acc. to DIN EN 61346-2:
- Q
- Reference code / acc. to DIN EN 81346-2:
- Q
- Setting range / Overload function L / IR can be switched on:
- No
- Short-circuit current making capacity (Icm) / at 240 V / rated value:
- 330kA
- Short-circuit current making capacity (Icm) / at 415 V / rated value:
- 242kA
- Standard:
- UL
- Sub Brand:
- 3VA
- Trip Type:
- ETU550 LSI LCD
- Type:
- 3VA6
- Type of electrical connection / for main current circuit:
- Without
- Voltage Rating:
- 480 V
- Width:
- 140
![Enclosed Circuit Breaker, Type Bolted Enclosure, Constructional Feature Explosionproof, Dust-Ignitionproof, Breaker Type FDB, Trip Type Thermal Magnetic, Voltage Rating 600 VAC/250 VDC, Current Rating 100 Ampere, Number of Poles 2, Hub Location Feed...](/images/e/eb2.jpg)
EB2F2W100
$3,551.46 /ea
Enclosed Circuit Breaker, Type Bolted Enclosure, Constructional Feature Explosionproof, Dust-Ignitionproof, Breaker Type FDB, Trip Type Thermal Magnetic, Voltage Rating 600 VAC/250 VDC, Current Rating 100 Ampere, Number of Poles 2, Hub Location Feed Through, Enclosure NEMA 3R/7B/7C/7D/9E/9F/9G, Enclosure Material Copper-Free Aluminum, Enclosure Finish 2 Coat Epoxy Enamel, Shaft/Handle Material Stainless Steel, Mounting Surface, Approval UL 1203, Applications Corrosive Atmosphere, Hazardous Location, Refinery, Chemical Plants, Petrochemical Plants, Processing Plants, Shaft/Bushing Material Stainless Steel
![Enclosed Circuit Breaker, Type Bolted Enclosure, Constructional Feature Explosionproof, Dust-Ignitionproof, Breaker Type FDB, Trip Type Thermal Magnetic, Voltage Rating 600 VAC/250 VDC, Current Rating 125 Ampere, Number of Poles 2, Hub Location Feed...](/images/e/eb2.jpg)
EB2F2W125
$5,172.97 /ea
Enclosed Circuit Breaker, Type Bolted Enclosure, Constructional Feature Explosionproof, Dust-Ignitionproof, Breaker Type FDB, Trip Type Thermal Magnetic, Voltage Rating 600 VAC/250 VDC, Current Rating 125 Ampere, Number of Poles 2, Hub Location Feed Through, Enclosure NEMA 3R/7B/7C/7D/9E/9F/9G, Enclosure Material Copper-Free Aluminum, Enclosure Finish 2 Coat Epoxy Enamel, Shaft/Handle Material Stainless Steel, Mounting Surface, Approval UL 1203, Applications Corrosive Atmosphere, Hazardous Location, Refinery, Chemical Plants, Petrochemical Plants, Processing Plants, Shaft/Bushing Material Stainless Steel
![Enclosed Circuit Breaker, Type Bolted Enclosure, Constructional Feature Explosionproof, Dust-Ignitionproof, Breaker Type FDB, Trip Type Thermal Magnetic, Voltage Rating 600 VAC/250 VDC, Current Rating 150 Ampere, Number of Poles 2, Hub Location Feed...](/images/e/eb2.jpg)
EB2F2W150
$5,172.97 /ea
Enclosed Circuit Breaker, Type Bolted Enclosure, Constructional Feature Explosionproof, Dust-Ignitionproof, Breaker Type FDB, Trip Type Thermal Magnetic, Voltage Rating 600 VAC/250 VDC, Current Rating 150 Ampere, Number of Poles 2, Hub Location Feed Through, Enclosure NEMA 3R/7B/7C/7D/9E/9F/9G, Enclosure Material Copper-Free Aluminum, Enclosure Finish 2 Coat Epoxy Enamel, Shaft/Handle Material Stainless Steel, Mounting Surface, Approval UL 1203, Applications Corrosive Atmosphere, Hazardous Location, Refinery, Chemical Plants, Petrochemical Plants, Processing Plants, Shaft/Bushing Material Stainless Steel
Product Image | |||
---|---|---|---|
EB2F2W100
Enclosed Circuit Breaker, Type Bolted Enclosure, Constructional Feature Explosionproof, Dust-Ignitionproof, Breaker Type FDB, Trip Type Thermal Magnetic, Voltage Rating 600 VAC/250 VDC, Current Rating 100 Ampere, Number of Poles 2, Hub Location Feed...
$3,551.46 / EA
|
EB2F2W125
Enclosed Circuit Breaker, Type Bolted Enclosure, Constructional Feature Explosionproof, Dust-Ignitionproof, Breaker Type FDB, Trip Type Thermal Magnetic, Voltage Rating 600 VAC/250 VDC, Current Rating 125 Ampere, Number of Poles 2, Hub Location Feed...
$5,172.97 / EA
|
EB2F2W150
Enclosed Circuit Breaker, Type Bolted Enclosure, Constructional Feature Explosionproof, Dust-Ignitionproof, Breaker Type FDB, Trip Type Thermal Magnetic, Voltage Rating 600 VAC/250 VDC, Current Rating 150 Ampere, Number of Poles 2, Hub Location Feed...
$5,172.97 / EA
|
|
Attributed Data | |||
Add a product to the cart | Show more details | Show more details | Show more details |