Call Us Today: (800) 462-7733
Enclosed soft starter, Controller 3RW40361BB14, H2 Std. duty current rating 42A, Control voltage 110-230 AC/DC, Non-combination type, Enclosure NEMA type 1, Indoor general purpose use
Enclosed soft starter, Controller 3RW40361BB14, H2 Std. duty current rating 42A, Control voltage 110-230 AC/DC, Non-combination type, Enclosure NEMA type 1, Indoor general purpose use

Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more information.

$15,384.24 / EA

manufacturer discounts
learn about discounts

  • $13,792.77 for $1,500.00+
  • $13,262.28 for $2,500.00+
  • $12,731.78 for $3,500.00+

In stock (0)
Lead time: over 7 days
may be longer on small orders

Enclosed soft starter, Controller 3RW40361BB14, H2 Std. duty current rating 42A, Control voltage 110-230 AC/DC, Non-combination type, Enclosure NEMA type 1, Indoor general purpose use

Enclosed soft starter, Controller 3RW40361BB14, H2 Std. duty current rating 42A, Control voltage 110-230 AC/DC, Non-combination type, Enclosure NEMA type 1, Indoor general purpose use

150

UPC
040892636314
UNSPSC
39121521
Country of Origin
US
Ambient temperature / during operation / maximum:
40 °C
Ambient temperature / during operation / minimum:
-20 °C
Certificate of suitability:
NEMAICS2;UL508A
Configuration of control input / 1:
ON/OFF
Configuration of relay output / 1:
ON/RUN
Configuration of relay output / 2:
BYPASSED
Configuration of relay output / 3:
OVERLOAD/FAILURE
Configuration of relay output / 4:
NA
Control supply voltage / at AC / at 50 Hz / Rated value / maximum:
230 V
Control supply voltage / at AC / at 50 Hz / Rated value / minimum:
110 V
Control supply voltage / at AC / at 60 Hz / Rated value / maximum:
230 V
Control supply voltage / at AC / at 60 Hz / Rated value / minimum:
110 V
Control supply voltage / at DC / Rated value / maximum:
230 V
Control supply voltage / at DC / Rated value / minimum:
110 V
Depth [in]:
13 in
Design of the housing:
Indoorgeneralpurposeuse
Display version:
4LEDs
Height [in]:
25 in
Installation altitude [ft] / at height above sea level / maximum:
6560 ft
Material / of the conductor / for load-side outgoing feeder:
CU
Material / of the conductor / for supply:
CU
Mounting type:
Surfacemountingandinstallation
Operating condition / for severe duty:
NA
Operating range factor supply voltage rated value / minimum:
0.85
Reset function:
Manual,automaticandremote
Trip CLASS:
Class5/15/20
Type of communication / optional:
None
Type of connectable conductor cross-section / for AWG conductors / for line-side / single or multi-stranded:
2/0...14AWG
Type of connectable conductor cross-section / for AWG conductors / for load-side outgoing feeder / single or multi-stranded:
18...2AWG(frontonly)or16...2AWG(backonly)or2x(16...2AWG)(bothfront&back)
Type of cooling:
None
Type of electrical connection / for auxiliary and control current circuit:
screw-typeterminals
Type of electrical connection / for load-side outgoing feeder:
Boxlug
Type of electrical connection / for supply voltage infeed -> line-side:
Boxlug
Width [in]:
18 in
mounting position:
Vertical
weight [lb]:
54 lb
Compare With Similar Items
MOTOR-ELEC WELLS #100846-10 (1399) (50321536)

32153G

$1,288.88 /ea

MOTOR-ELEC WELLS #100846-10 (1399) (50321536)

MOTOR ASSEMBLY (50121758)

HB.9050

$600.18 /ea

MOTOR ASSEMBLY (50121758)

MOTOR ASSY, 115 VOLT (50015583)

HB.9052

$375.38 /ea

MOTOR ASSY, 115 VOLT (50015583)

Recently Viewed

  • placeholder image

    CS6364-COOP

    COOPER WIRING DEVICES
    Eaton locking connector, #10-6 AWG, 50A, Industrial, 125/250V, Back wiring, Steel, Armored, Non-NEMA, Three-pole, Four-wire, Steel, 0.68 to 1.13 in
    See more details
  • placeholder image

    73ER34BFA

    SIEMENS INDUSTRY, INC.
    Enclosed soft starter, Controller 3RW40361BB14, H2 Std. duty current rating 42A, Control voltage 110-230 AC/DC, Non-combination type, Enclosure NEMA t...
    See more details

ADDED TO CART