Call Us Today: (800) 462-7733
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA62 FRAME WITH HIGH (CLASS L) BREAKING CAPACITY. 250A 4-POLE (50KAIC AT 600V) (150KAIC AT 480V). ETU820 TRIP UNIT LCD LI WITH METERING. SPECIAL FEATURES WITHOUT LUGS.. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.

Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more information.

3VA6225-8KL41-0AA0

$11,366.55 / EA

manufacturer discounts
learn about discounts

  • $10,190.70 for $1,500.00+
  • $9,798.75 for $2,500.00+
  • $9,406.80 for $3,500.00+
Available to order

Local stock: 0
Lead time: over 7 working days

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA62 FRAME WITH HIGH (CLASS L) BREAKING CAPACITY. 250A 4-POLE (50KAIC AT 600V) (150KAIC AT 480V). ETU820 TRIP UNIT LCD LI WITH METERING. SPECIAL FEATURES WITHOUT LUGS.. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA62 FRAME WITH HIGH (CLASS L) BREAKING CAPACITY. 250A 4-POLE (50KAIC AT 600V) (150KAIC AT 480V). ETU820 TRIP UNIT LCD LI WITH METERING. SPECIAL FEATURES WITHOUT LUGS.. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.

150

UPC
804766308925
UNSPSC
39121601
Country of Origin
CZ
Number Of Poles:
4
Type:
3VA6
Voltage Rating:
480 V
Adjustable pick-up value current / of instantaneous short-circuit trip unit / Full-scale value:
2500
Adjustable pick-up value current / of instantaneous short-circuit trip unit / initial value:
375
Adjustable pick-up value current / of the current-dependent overload release / Full-scale value:
250
Adjustable pick-up value current / of the current-dependent overload release / initial value:
100
Ambient temperature / during storage / maximum:
80
Arrangement of electrical connectors / for main current circuit:
Withoutconnection
Connection:
punched copper bar without any lug
Current Rating:
250 A
Frame:
250A
Height:
198
Interrupt Rating:
WITH 150kA INTERRUPTION RATING
Length:
5.51
Maximum short-circuit current breaking capacity (Icu) / at 240 V / rated value:
200
Maximum short-circuit current breaking capacity (Icu) / at 415 V / rated value:
150
Mounting type:
fixedmounting
Number Of Poles:
4
Operational short-circuit current breaking capacity (Ics) / at 240 V / rated value:
200kA
Operational short-circuit current breaking capacity (Ics) / at 415 V / rated value:
150kA
Operational short-circuit current breaking capacity (Ics) / at 690 V / rated value:
3
Power loss [W] / for rated value of the current / at AC / in hot operating state / per pole:
14
Product variations:
Advancedapplications
Protection class IP:
IP40
Protection class IP / on the front:
IP40
Reference code / acc. to DIN EN 61346-2:
Q
Setting range / Overload function L / IR can be switched on:
No
Standard:
UL
Sub Brand:
3VA
Switching capacity class of the circuit breaker:
L
Trip Type:
ETU820 LI LCD
Type:
3VA6
Type of electrical connection / for main current circuit:
Without
Voltage Rating:
480 V
Width:
140

ADDED TO CART