Call Us Today: (800) 462-7733
CIRCUIT-BREAKER VL 150 UL TYPE DG (CAT NO. HDK3B050) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER ACC. UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA@480V AND 18KA@600/347V (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE TM, LI TU= 40 DEGR. CELSIUS IN=50A, RATED CURRENT II= 450...700A SHORT-CIRCUIT PROTECTION IR= 50A OVERCURRENT RELEASE F. PLANT PROTECTION W/O CONNECTION ACCESSORIES WITHOUT AUXILIARY RELEASE AUXILIARY/ALARM SWITCH KIT 2HS(1NO+1NC)+1AS(1NO)

Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more information.

3VL2505-2KN30-0AD1

$11,539.35 / EA

manufacturer discounts
learn about discounts

  • $10,345.62 for $1,500.00+
  • $9,947.71 for $2,500.00+
  • $9,549.80 for $3,500.00+

In stock (0)
Lead time: over 7 days
may be longer on small orders

CIRCUIT-BREAKER VL 150 UL TYPE DG (CAT NO. HDK3B050) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER ACC. UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA@480V AND 18KA@600/347V (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE TM, LI TU= 40 DEGR. CELSIUS IN=50A, RATED CURRENT II= 450...700A SHORT-CIRCUIT PROTECTION IR= 50A OVERCURRENT RELEASE F. PLANT PROTECTION W/O CONNECTION ACCESSORIES WITHOUT AUXILIARY RELEASE AUXILIARY/ALARM SWITCH KIT 2HS(1NO+1NC)+1AS(1NO)

CIRCUIT-BREAKER VL 150 UL TYPE DG (CAT NO. HDK3B050) NON-INTERCHANGEABLE FRAME W. APPROBATION CIRCUIT-BREAKER ACC. UL489 HIGH BREAKING CAPACITY 3-POLE, NEMA RATING 65KA@480V AND 18KA@600/347V (MOLDED CASE CIRCUIT BREAKER) OVERCURRENT RELEASE TM, LI TU= 40 DEGR. CELSIUS IN=50A, RATED CURRENT II= 450...700A SHORT-CIRCUIT PROTECTION IR= 50A OVERCURRENT RELEASE F. PLANT PROTECTION W/O CONNECTION ACCESSORIES WITHOUT AUXILIARY RELEASE AUXILIARY/ALARM SWITCH KIT 2HS(1NO+1NC)+1AS(1NO)

150

UPC
887621125905
UNSPSC
39121601
Country of Origin
DE
Material:
MOLDED CASE CIRCUIT BREAKER
Number Of Poles:
3
Type:
DG
Voltage Rating:
600Y V
Adjustable pick-up value current / of instantaneous short-circuit trip unit / Full-scale value:
700 A
Adjustable pick-up value current / of instantaneous short-circuit trip unit / initial value:
450 A
Adjustable pick-up value current / of the current-dependent overload release / Full-scale value:
50 A
Adjustable pick-up value current / of the current-dependent overload release / initial value:
50 A
Ambient temperature / during operation / maximum:
70 °C
Auxiliary Contacts:
1
Auxiliary release:
WITHOUTAUXILIARYRELEASE
Connection:
withoutconnectionaccessoires
Current Rating:
50 A
Derating temperature / for the rated value of the continuous current / acc. to UL 489:
40.0°C
Diken-export / tripping characteristics / Upper tolerance band:
AK_VL250_TM_I_u.txt
Frame:
DG
Frequency Rating:
50/60 Hz
Interrupt Rating:
18KA kA
Material:
MOLDED CASE CIRCUIT BREAKER
Number Of Poles:
3
Operating Temperature:
40DEGC °C
Operating voltage / for main current circuit / at AC / at 50 Hz / acc. to UL 489 / maximum:
600.0V
Operating voltage / for main current circuit / at AC / at 50 Hz / maximum:
690.0V
Operating voltage / for main current circuit / at AC / at 60 Hz / acc. to UL 489 / maximum:
600.0V
Operating voltage / for main current circuit / at AC / at 60 Hz / maximum:
690.0V
Product component / Voltage trigger:
No
Product function / for neutral conductors / Short-circuit and overload proof:
No
Protection class IP:
IP20
Reference code / acc. to DIN 40719 extended according to IEC 204-2 / acc. to IEC 750:
Q
Standard:
UL
Sub Brand:
VL
Trip Type:
THERMAL MAGNETIC TRIP UNIT
Tripping characteristics / Lower tolerance band:
AK_VL160x_TM_I_o.txt
Type:
DG
Voltage Rating:
600Y V
Compare With Similar Items
BREAKER-CIRCUIT (50453750)

45375G

$48.43 /ea

BREAKER-CIRCUIT (50453750)

SWITCH,CIRCUIT BREAKER (52040980)

10712-GRNL

$80.56 /ea

SWITCH,CIRCUIT BREAKER (52040980)

SWITCH,CIRCUIT BREAKER (120V 16A S-P) (91861527)

86152-GRNL

$201.84 /ea

SWITCH,CIRCUIT BREAKER (120V 16A S-P) (91861527)

ADDED TO CART