Enclosed soft starter, Controller 3RW40736BB34, H2 Std. duty current rating 205A, Control voltage 115 AC, Non-combination type, Enclosure NEMA type 1, Indoor general purpose use
Enclosed soft starter, Controller 3RW40736BB34, H2 Std. duty current rating 205A, Control voltage 115 AC, Non-combination type, Enclosure NEMA type 1, Indoor general purpose use
150
- UPC
- 783087820531
- Ambient temperature / during operation / maximum:
- 40 °C
- Ambient temperature / during operation / minimum:
- -20 °C
- Ambient temperature / during storage / maximum:
- 65 °C
- Ambient temperature / during storage / minimum:
- -30 °C
- Ambient temperature [°F] / during operation / maximum:
- 104 °F
- Ambient temperature [°F] / during operation / minimum:
- -4 °F
- Ambient temperature [°F] / during storage / maximum:
- 149 °F
- Ambient temperature [°F] / during storage / minimum:
- -22 °F
- Consumed active power [hp] / at severe duty / maximum:
- 60 hp
- Consumed active power [hp] / at standard duty / maximum:
- 75 hp
- Control supply voltage / at AC / at 50 Hz / Rated value / maximum:
- 115 V
- Control supply voltage / at AC / at 50 Hz / Rated value / minimum:
- 115 V
- Control supply voltage / at AC / at 60 Hz / Rated value / maximum:
- 115 V
- Control supply voltage / at AC / at 60 Hz / Rated value / minimum:
- 115 V
- Depth [in]:
- 20 in
- Design of the fuse link / for short-circuit protection of the main circuit / required:
- 10kA@600V(ClassHorK);100kA@600V(ClassRorJ)
- Design of the short-circuit trip:
- Thermalmagneticcircuitbreaker
- Height [in]:
- 36 in
- Installation altitude [ft] / at height above sea level / maximum:
- 6560 ft
- Material / of the conductor / for load-side outgoing feeder:
- CU
- Material / of the conductor / for supply:
- ALorCU
- Number of poles / for main current circuit:
- 3
- Operating current / at severe duty / rated value:
- 185 A
- Operating current / at standard duty / rated value:
- 205 A
- Operating range factor supply voltage rated value / maximum:
- 1.1
- Operating range factor supply voltage rated value / minimum:
- 0.85
- Operating voltage / at AC-3 / Rated value / maximum:
- 230 V
- Operating voltage / for main current circuit / at AC / at 60 Hz / maximum:
- 230 V
- Product function / ramp-up (soft starting)/ramp-down (soft stop):
- Yes
- Ramp-up time / maximum:
- 20 s
- Type of connectable conductor cross-section / for AWG conductors / for load-side outgoing feeder / single or multi-stranded:
- 3/0...600kcmil(frontonly)or250...500kcmil(backonly)or2x500kcmil(bothfront&back)AWG
- Type of electrical connection / for auxiliary and control current circuit:
- screw-typeterminals
- Type of electrical connection / for load-side outgoing feeder:
- Boxlug
- Width [in]:
- 22 in
- weight [lb]:
- 114 lb