Call Us Today: (800) 462-7733

3RB2906-2DG1

SKU: 3RB2906-2DG1

MPN: 3RB2906-2DG1

Key specs

View all
Adjustable pick-up value current / of the current-dependent overload release / Full-scale value
25 A
Adjustable pick-up value current / of the current-dependent overload release / initial value
2.4 A
Application area
foroverloadrelays
Certificate of suitability / according to ATEX directive 2014/34/EU
PTB05ATEX3022
Mounting type
stand-aloneinstallation
Product designation
Currentmeasuringmodule

Description

Product overview

Current transformer 2.4...25 a for 3RB22/23 size s00/s0 stand-alone installation main circuit through transf. aux. circuit --

Current transformer 2.4...25 a for 3RB22/23 size s00/s0 stand-alone installation main circuit through transf. aux. circuit --

Manufacturer highlights

Additional manufacturer notes

Feed description
S-A 3RB2906-2DG1 TRANSFORMER,CURREN
Invoice description
TRANSFORMER,CURRENT 2.4...25 A FOR 3RB2

Specifications

UPC
040892553734
UNSPSC
39121552
Country of Origin
DE
Adjustable pick-up value current / of the current-dependent overload release / Full-scale value
25 A
Adjustable pick-up value current / of the current-dependent overload release / initial value
2.4 A
Application area
foroverloadrelays
Certificate of suitability / according to ATEX directive 2014/34/EU
PTB05ATEX3022
Mounting type
stand-aloneinstallation
Product designation
Currentmeasuringmodule
Type of electrical connection / for main current circuit
straight-throughtransformers
Type of protection
PTB05ATEX3022ExII(2)GD
Type of protection / according to ATEX directive 2014/34/EU
ExII(2)GD
product brand name
SIRIUS

Do you have a question about 3RB2906-2DG1?

Videos & documents

Documents

Similar items

Compare alternates in this category before ordering.

Current transformer 0.3...3 a for 3RB22/23 size s00/s0 stand-alone installationmain circuit through transf. aux. circuit --

Similar item

3RB2906-2BG1

Current transformer 0.3...3 a for 3RB22/23 size s00/s0 stand-alone installationmain circuit through transf. aux. circuit --

$246.50 / EA

Available to order

View details
FUNCTION MODULE FOR AS-I, DIRECT START, SCREW CONNECTION, MOUNTED ON CONTACTORS3RT2 S00/ S0 COMM. CAPABLE CONTACTOR REQUIRED

Similar item

3RA27121AA00

FUNCTION MODULE FOR AS-I, DIRECT START, SCREW CONNECTION, MOUNTED ON CONTACTORS3RT2 S00/ S0 COMM. CAPABLE CONTACTOR REQUIRED

$510.55 / EA

Available to order

View details

Specification comparison

Scan the attributes that differ across these alternatives.

3RB2906-2BG1 View key specs
Price

$246.50 / EA

Availability
Available to order
Adjustable pick-up value current / of the current-dependent overload release / Full-scale value
3 A
Adjustable pick-up value current / of the current-dependent overload release / initial value
0.3 A
Ambient temperature / during operation / maximum
—
Ambient temperature / during operation / minimum
—
Application area
foroverloadrelays
Certificate of suitability / according to ATEX directive 2014/34/EU
PTB05ATEX3022
View full product details
CLM4379771 View key specs
Price

$186.53 / EA

Availability
Available to order
Adjustable pick-up value current / of the current-dependent overload release / Full-scale value
—
Adjustable pick-up value current / of the current-dependent overload release / initial value
—
Ambient temperature / during operation / maximum
—
Ambient temperature / during operation / minimum
—
Application area
—
Certificate of suitability / according to ATEX directive 2014/34/EU
—
View full product details
CLM4379774 View key specs
Price

$737.06 / EA

Availability
Available to order
Adjustable pick-up value current / of the current-dependent overload release / Full-scale value
—
Adjustable pick-up value current / of the current-dependent overload release / initial value
—
Ambient temperature / during operation / maximum
—
Ambient temperature / during operation / minimum
—
Application area
—
Certificate of suitability / according to ATEX directive 2014/34/EU
—
View full product details
CLM4379784 View key specs
Price

$805.27 / EA

Availability
Available to order
Adjustable pick-up value current / of the current-dependent overload release / Full-scale value
—
Adjustable pick-up value current / of the current-dependent overload release / initial value
—
Ambient temperature / during operation / maximum
—
Ambient temperature / during operation / minimum
—
Application area
—
Certificate of suitability / according to ATEX directive 2014/34/EU
—
View full product details
CLM4379794 View key specs
Price

$858.17 / EA

Availability
Available to order
Adjustable pick-up value current / of the current-dependent overload release / Full-scale value
—
Adjustable pick-up value current / of the current-dependent overload release / initial value
—
Ambient temperature / during operation / maximum
—
Ambient temperature / during operation / minimum
—
Application area
—
Certificate of suitability / according to ATEX directive 2014/34/EU
—
View full product details
3RA27121AA00 View key specs
Price

$510.55 / EA

Availability
Available to order
Adjustable pick-up value current / of the current-dependent overload release / Full-scale value
—
Adjustable pick-up value current / of the current-dependent overload release / initial value
—
Ambient temperature / during operation / maximum
60 °C
Ambient temperature / during operation / minimum
-25 °C
Application area
—
Certificate of suitability / according to ATEX directive 2014/34/EU
—
View full product details