Key specs
View all- Average probability of failure on demand (PFDavg) / with low demand rate / acc. to IEC 61508
- 0.0000436 1/y
- Connectable conductor cross-section / for auxiliary contacts / finely stranded / with core end processing / maximum
- 1.5 mm2
- Connectable conductor cross-section / for auxiliary contacts / finely stranded / with core end processing / minimum
- 0.25 mm2
- Connectable conductor cross-section / for auxiliary contacts / finely stranded / without core end processing / maximum
- 1.5 mm2
- Connectable conductor cross-section / for auxiliary contacts / finely stranded / without core end processing / minimum
- 0.25 mm2
- Connectable conductor cross-section / for auxiliary contacts / single or multi-stranded / maximum
- 1.5 mm2
Description
Product overview
SIRIUS, 3RK32 EXPANSION MODULE FOR MODULAR 3RK3 SAFETY SYSTEM 4/8 F-RO, 24 V DC/2A PARAMETERIZABLE VIA SW MSS ES 22.5MM MODULE WIDTH CAGE-CLAMP TERMINAL UP TO CATEGORY 4 (EN954-1) UP TO SIL3 (IEC 61508) UP TO PERFORMANCE LEVEL E (ISO 13849-1)
SIRIUS, 3RK32 EXPANSION MODULE FOR MODULAR 3RK3 SAFETY SYSTEM 4/8 F-RO, 24 V DC/2A PARAMETERIZABLE VIA SW MSS ES 22.5MM MODULE WIDTH CAGE-CLAMP TERMINAL UP TO CATEGORY 4 (EN954-1) UP TO SIL3 (IEC 61508) UP TO PERFORMANCE LEVEL E (ISO 13849-1)
Manufacturer highlights
Additional manufacturer notes
- Short name
- S-A
- Feed description
- S-A 3RK32512AA10 MSS exp. mod., 4/8
- Invoice description
- MSS exp. mod., 4/8 F-RO, spring term
Specifications
- UPC
- 754554971599
- Average probability of failure on demand (PFDavg) / with low demand rate / acc. to IEC 61508
- 0.0000436 1/y
- Connectable conductor cross-section / for auxiliary contacts / finely stranded / with core end processing / maximum
- 1.5 mm2
- Connectable conductor cross-section / for auxiliary contacts / finely stranded / with core end processing / minimum
- 0.25 mm2
- Connectable conductor cross-section / for auxiliary contacts / finely stranded / without core end processing / maximum
- 1.5 mm2
- Connectable conductor cross-section / for auxiliary contacts / finely stranded / without core end processing / minimum
- 0.25 mm2
- Connectable conductor cross-section / for auxiliary contacts / single or multi-stranded / maximum
- 1.5 mm2
- Connectable conductor cross-section / for auxiliary contacts / single or multi-stranded / minimum
- 0.25 mm2
- Number of outputs / as contact-affected switching element / safety-related / 1-channel
- 8