Call Us Today: (800) 462-7733
Digital monitoring relay 3-phase supply voltage autom. phase sequence correction phase failure 3 x 160 to 690 v 50 to 60 HZ AC undervoltage and overvoltage 160-690 v hysteresis 1-20 v off delay 0-20 s asymmetry 0-20% 1 co for phase correction 1 co for line supply faults spring-type connection system
Digital monitoring relay 3-phase supply voltage autom. phase sequence correction phase failure 3 x 160 to 690 v 50 to 60 HZ AC undervoltage and overvoltage 160-690 v hysteresis 1-20 v off delay 0-20 s asymmetry 0-20% 1 co for phase correction 1 co for line supply faults spring-type connection system

Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more information.

$381.58 / EA

manufacturer discounts
learn about discounts

  • $342.11 for $1,500.00+
  • $328.95 for $2,500.00+
  • $315.79 for $3,500.00+

In stock (0)
Lead time: over 7 days
may be longer on small orders

Digital monitoring relay 3-phase supply voltage autom. phase sequence correction phase failure 3 x 160 to 690 v 50 to 60 HZ AC undervoltage and overvoltage 160-690 v hysteresis 1-20 v off delay 0-20 s asymmetry 0-20% 1 co for phase correction 1 co for line supply faults spring-type connection system

Digital monitoring relay 3-phase supply voltage autom. phase sequence correction phase failure 3 x 160 to 690 v 50 to 60 HZ AC undervoltage and overvoltage 160-690 v hysteresis 1-20 v off delay 0-20 s asymmetry 0-20% 1 co for phase correction 1 co for line supply faults spring-type connection system

150

UPC
754554937205
UNSPSC
39122334
Country of Origin
DE
Accuracy of digital display:
+/-1digit
Adjustable response delay time / with lower or upper limit violation / Full-scale value:
20 s
Ambient temperature / during operation / maximum:
60 °C
Ambient temperature / during operation / minimum:
-25 °C
Control supply voltage / at AC / at 50 Hz / Rated value / maximum:
690.0 V
Control supply voltage / at AC / at 50 Hz / Rated value / minimum:
160.0 V
Control supply voltage / at AC / at 60 Hz / Rated value / maximum:
690.0 V
Control supply voltage / at AC / at 60 Hz / Rated value / minimum:
160.0 V
Relative metering precision:
5 %
Type of electrical connection:
spring-loadedterminals
Compare With Similar Items
Cabinet unit for use in 24 V DC relay,1changeover conta.,24V DC

3TX7014-7BM00

$25.81 /ea

Cabinet unit for use in 24 V DC relay,1changeover conta.,24V DC

Attributed Data Included
Number of CO contacts / for auxiliary contacts 1 Yes
Protection class IP IP00 Yes
Reference code / acc. to DIN 40719 extended according to IEC 204-2 / acc. to IEC 750 K Yes
Type of voltage DC Yes
Cabinet unit for use in 24 V DC coil voltage 24 V DC relay 1ch.cont. hard gold-plat.

3TX7014-7BM02

$40.06 /ea

Cabinet unit for use in 24 V DC coil voltage 24 V DC relay 1ch.cont. hard gold-plat.

Attributed Data Included
Number of CO contacts / for auxiliary contacts 1 Yes
Protection class IP IP00 Yes
Reference code / acc. to DIN 40719 extended according to IEC 204-2 / acc. to IEC 750 K Yes
Type of voltage DC Yes
CABINET UNIT FOR USE IN 110 / 230 V AC/DC RELAY,1CHANGEOVER CONTA.,60V DC

3TX7014-7BP00

$35.47 /ea

CABINET UNIT FOR USE IN 110 / 230 V AC/DC RELAY,1CHANGEOVER CONTA.,60V DC

Attributed Data Included
Number of CO contacts / for auxiliary contacts 1 Yes
Protection class IP IP00 Yes
Reference code / acc. to DIN 40719 extended according to IEC 204-2 / acc. to IEC 750 K Yes
Type of voltage DC Yes

ADDED TO CART