$264.86 / EA
manufacturer discounts
learn about discounts
- $237.46 for $1,500.00+
- $228.33 for $2,500.00+
- $219.19 for $3,500.00+
In stock (0)
Lead time: over 7 days
may be longer on small orders
Digital monitoring relay voltage monitoring, 22.5 mm from 17 to 275 V AC/DC over- and undershoot internal power supply DC and AC 50 to 60 HZ spurious peak lag 0.1 to 20 s hysteresis 0.1 to 150 v 1 changeover contact with or without error memory screw terminal replacement product for 3ug3534, 3ug3535
Digital monitoring relay voltage monitoring, 22.5 mm from 17 to 275 V AC/DC over- and undershoot internal power supply DC and AC 50 to 60 HZ spurious peak lag 0.1 to 20 s hysteresis 0.1 to 150 v 1 changeover contact with or without error memory screw terminal replacement product for 3ug3534, 3ug3535
150
- UPC
- 754554931487
- UNSPSC
- 39122333
- Country of Origin
- DE
- Accuracy of digital display:
- +/-1digit
- Adjustable response delay time / when starting / Full-scale value:
- 20 s
- Adjustable response delay time / with lower or upper limit violation / Full-scale value:
- 20 s
- Ambient temperature / during operation / maximum:
- 60 °C
- Ambient temperature / during operation / minimum:
- -25 °C
- Control supply voltage / at DC / Rated value / maximum:
- 275.0 V
- Relative metering precision:
- 5 %
- Relative temperature-related measurement deviation:
- 0.1 %
- Type of electrical connection:
- screw-typeterminals
- Type of voltage / for monitoring:
- AC/DC
86403-GRNL
$249.69 /ea
RELAY, SOLID STATE 240V 45A 25-65HZ (91864038)
3UG46312AW30
$291.80 /ea
Digital monitoring relay voltage monitoring, 22.5mm from 0.1 to 60V AC/DC overshoot and undershoot AC/DC 24 to 240V DC and AC 50 to 60 HZ spike delay 0.1 to 20s hysteresis 0.1 to 30v 1 changeover contact w. or w/o error log spring-loaded type
Attributed Data | Included |
---|---|
Accuracy of digital display | +/-1digit Yes |
Type of electrical connection | spring-loadedterminals Yes |
Type of voltage / for monitoring | AC/DC Yes |
3UG4651-1AA30
$473.61 /ea
Digital monitoring relay speed monitoring from 0.1 to 2200 rev/min overshoot and undershoot AC/DC 24V DC and AC 50 to 60 HZ startup delay 1 to 900s tripping delayed 0.1 to 99.9s hysteresis 0.1 to 99 rev/min 1 changeover contact w. or w/o error log screw terminal replacement product f. 3ug3051
Attributed Data | Included |
---|---|
Operating range factor control supply voltage rated value / at DC / Full-scale value | 1.1 Yes |
Operating range factor control supply voltage rated value / at DC / initial value | 0.8 Yes |
Product Image | |||
---|---|---|---|
86403-GRNL
RELAY, SOLID STATE 240V 45A 25-65HZ (91864038)
$249.69 / EA
|
3UG46312AW30
Digital monitoring relay voltage monitoring, 22.5mm from 0.1 to 60V AC/DC overshoot and undershoot AC/DC 24 to 240V DC and AC 50 to 60 HZ spike delay 0.1 to 20s hysteresis 0.1 to 30v 1 changeover contact w. or w/o error log spring-loaded type
$291.80 / EA
|
3UG4651-1AA30
Digital monitoring relay speed monitoring from 0.1 to 2200 rev/min overshoot and undershoot AC/DC 24V DC and AC 50 to 60 HZ startup delay 1 to 900s tripping delayed 0.1 to 99.9s hysteresis 0.1 to 99 rev/min 1 changeover contact w. or w/o error log sc...
$473.61 / EA
|
|
Attributed Data | |||
Accuracy of digital display | +/-1digit +/-1digit | ||
Adjustable response delay time / with lower or upper limit violation / Full-scale value | 20 s 20 s | ||
Adjustable response value speed / Full-scale value | 2200 1/min 2200 1/min | ||
Adjustable response value speed / initial value | 0.1 1/min 0.1 1/min | ||
Ambient temperature / during operation / maximum | 60 °C 60 °C | ||
Ambient temperature / during operation / minimum | -25 °C -25 °C | ||
Buffering time / in the event of power failure / minimum | 10 ms 10 ms | ||
Control supply voltage / at DC / Rated value / maximum | 240.0 V 240.0 V | ||
Control supply voltage / at DC / Rated value / minimum | 24.0 V 24.0 V | ||
Input current / at digital input 1 / maximum | 50 mA 50 mA | ||
Input current / at digital input 2 / Full-scale value for signal<0> recognition | 1.2 mA 1.2 mA | ||
Input current / at digital input 2 / Full-scale value for signal<1> recognition | 8.2 mA 8.2 mA | ||
Input current / at digital input 2 / initial value for signal<1>-recognition | 2.1 mA 2.1 mA | ||
Operating range factor control supply voltage rated value / at DC / Full-scale value | 1.1 1.1 | ||
Operating range factor control supply voltage rated value / at DC / initial value | 0.8 0.8 | ||
Relative metering precision | 5 % 5 % | ||
Relative temperature-related measurement deviation | 0.1 % 0.1 % | ||
Type of electrical connection | spring-loadedterminals spring-loadedterminals | ||
Type of voltage / for monitoring | AC/DC AC/DC | ||
Add a product to the cart | Show more details | Show more details | Show more details |