Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more
information.
$7,739.17 / EA
manufacturer discounts
learn about discounts
- $6,938.57 for $1,500.00+
- $6,671.70 for $2,500.00+
- $6,404.83 for $3,500.00+
Local stock: 0
Lead time:
over 7 working days
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH THERMAL - MAGNETIC TRIP UNIT. 3VA55 FRAME WITH MEDIUM (CLASS H) BREAKING CAPACITY. 600A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). TM230 TRIP UNIT WITH FIXED Ir ADJUSTABLE Ii. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D) IN 11.1 x 12.5 x 5.8.
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH THERMAL - MAGNETIC TRIP UNIT. 3VA55 FRAME WITH MEDIUM (CLASS H) BREAKING CAPACITY. 600A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). TM230 TRIP UNIT WITH FIXED Ir ADJUSTABLE Ii. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D) IN 11.1 x 12.5 x 5.8.
150
- UPC
- 804766978326
- Number Of Poles:
- 4
- Adjustable pick-up value current / of instantaneous short-circuit trip unit / initial value:
- 3000
- Ambient temperature / during operation / maximum:
- 70 °C
- Ambient temperature / during operation / minimum:
- -25 °C
- Ambient temperature / during storage / maximum:
- 80 °C
- Ambient temperature / during storage / minimum:
- -40 °C
- Breaking capacity current / at AC / at 240 V / acc. to UL 489 / rated value:
- 100 kA
- Breaking capacity current / at AC / at 480 V / acc. to UL 489 / rated value:
- 65 kA
- Breaking capacity current / at AC / at 600 V / acc. to UL 489 / rated value:
- 25 kA
- Certificate of suitability / as approval for NAVAL (no combat vessels) / Supplement SB:
- No
- Depth [in]:
- 4.7 in
- Design of the N-conductor protection:
- Without
- Design of the load switch / acc. to UL 489 / Heating, Air Conditioning, and Refrigeration circuit breaker (HACR Type):
- Yes
- Electrical endurance (switching cycles) / at 480 V / at 50/60 Hz:
- 5100
- Electrical endurance (switching cycles) / at 600 V / at 50/60 Hz:
- 3500
- Electrical endurance (switching cycles) / at AC-1 / at 380/415 V / at 50/60 Hz:
- 5100
- Electrical endurance (switching cycles) / at AC-1 / at 690 V / at 50/60 Hz:
- 3500
- Height:
- 328 mm
- Height [in]:
- 12.6 in
- Marking / of circuit breaker / acc. to UL 489 / 100%-rated breaker:
- No
- Maximum short-circuit current breaking capacity (Icu) / at 240 V / rated value:
- 100
- Maximum short-circuit current breaking capacity (Icu) / at 415 V / rated value:
- 70
- Mechanical service life (switching cycles) / typical:
- 10000
- Number Of Poles:
- 4
- Operational short-circuit current breaking capacity (Ics) / at 240 V / rated value:
- 100kA
- Power loss [W] / for rated value of the current / at AC / in hot operating state / per pole:
- 54 W
- Protection class IP / on the front:
- IP40
- Reference code / acc. to DIN EN 81346-2:
- Q
- Setting range / Overload function L / Delay time tR / I**2t characteristic curve / max:
- 1
- Setting range / Overload function L / Delay time tR / I**2t characteristic curve / min:
- 1
- Setting range / Overload function L / Setting current IR / max:
- 1
- Setting range / Overload function L / Setting current IR / min:
- 1
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / max:
- 10
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / minimum:
- 5
- Short-circuit current making capacity (Icm) / at 240 V / rated value:
- 220.0kA
- Short-circuit current making capacity (Icm) / at 690 V / rated value:
- 74.00kA
- Width:
- 280 mm
- Width [in]:
- 11 in