Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more
information.
$10,139.33 / EA
manufacturer discounts
learn about discounts
- $9,090.43 for $1,500.00+
- $8,740.80 for $2,500.00+
- $8,391.17 for $3,500.00+
Local stock: 0
Lead time:
over 7 working days
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH THERMAL - MAGNETIC TRIP UNIT. 3VA55 FRAME WITH MEDIUM HIGH (CLASS C) BREAKING CAPACITY. 600A 4-POLE(35KAIC AT 600V) (100KAIC AT 480V). TM230 TRIP UNIT WITH FIXED Ir ADJUSTABLE Ii. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x Hx D) IN 11.1 x 12.5 x 5.8.
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH THERMAL - MAGNETIC TRIP UNIT. 3VA55 FRAME WITH MEDIUM HIGH (CLASS C) BREAKING CAPACITY. 600A 4-POLE(35KAIC AT 600V) (100KAIC AT 480V). TM230 TRIP UNIT WITH FIXED Ir ADJUSTABLE Ii. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x Hx D) IN 11.1 x 12.5 x 5.8.
150
- UPC
- 804766978371
- Number Of Poles:
- 4
- Continuous current / rated value / maximum:
- 800A
- Design of short-circuit protection:
- ForswitchingpowervaluesinDCnetworks,seethe3VAmoldedcasecircuitbreakerdevicemanual;linktobefoundunderService&Supportinthelastchapter
- Ground fault monitoring version:
- Without
- Height:
- 328 mm
- Maximum short-circuit current breaking capacity (Icu) / at 690 V / rated value:
- 35
- N-Leiter Schutz / einstellbar:
- Yes
- N-Leiterschutz N / Einstellparameter Strom InN / Einheit der Werteliste:
- Unit
- N-Leiterschutz N / Einstellparameter Strom InN / Format der Werteliste:
- xIn
- N-leiter-schutz / Ein-/Ausschaltbar:
- No
- Number Of Poles:
- 4
- Operating voltage / at AC / at 50/60 Hz / rated value:
- 600 V
- Operating voltage / at DC / rated value:
- 600
- Operational short-circuit current breaking capacity (Ics) / at 415 V / rated value:
- 85kA
- Operational short-circuit current breaking capacity (Ics) / at 690 V / rated value:
- 19
- Overcurrent release / Protective functions:
- LI
- Product variations:
- GeneralApplications
- Protection class IP / on the front:
- IP40
- Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Factor:
- s
- Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Factor of grading:
- Fixed
- Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Grading:
- 1
- Setting range / Overload function L / I**4tI**2t can be changed over:
- No
- Setting range / Overload function L / IR can be switched on:
- Yes
- Setting range / Overload function L / Setting current IR / Factor:
- xIn
- Setting range / Overload function L / Setting current IR / Factor of grading:
- Unit
- Setting range / Overload function L / Setting current IR / Grading:
- 1
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / Factor:
- xIn
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / Factor of grading:
- Unit
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / Grading:
- 5;6;7;8;9;10
- Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / can be switched on/off:
- No
- Setting range / ground fault function G / lg function selectable:
- No
- Short-circuit current making capacity (Icm) / at 415 V / rated value:
- 242.0kA
- Switching capacity class of the circuit breaker:
- C
- Width:
- 280 mm
- circuit-breaker / Design:
- 3VA5
- i-trip unit / can be switched ON/OFF:
- No
- version / Overcurrent release / Adjustability / Overload function L:
- Yes
- version / Overcurrent release / Adjustability / Short-circuit function, instantaneous I:
- Yes