SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA61 FRAME WITH MEDIUM (CLASS M) BREAKING CAPACITY. 100A 4-POLE (18KAIC AT 600V) (35KAIC AT 480V). ETU330 TRIP UNIT LIG. SPECIAL FEATURES WITHOUT LUGS 100 PERCENT RATED. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA61 FRAME WITH MEDIUM (CLASS M) BREAKING CAPACITY. 100A 4-POLE (18KAIC AT 600V) (35KAIC AT 480V). ETU330 TRIP UNIT LIG. SPECIAL FEATURES WITHOUT LUGS 100 PERCENT RATED. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.
150
- UPC
- 804766307089
- UNSPSC
- 39121601
- Country of Origin
- CZ
- Number Of Poles:
- 4
- Type:
- 3VA6
- Voltage Rating:
- 480 V
- Adjustable pick-up value current / for G-tripping / with standard characteristic / Full-scale value:
- 100.00A
- Ambient temperature / during operation / maximum:
- 70
- Ambient temperature / during operation / minimum:
- -25
- Ambient temperature / during storage / maximum:
- 80
- Arrangement of electrical connectors / for main current circuit:
- Withoutconnection
- Connection:
- punched copper bar without any lug
- Current Rating:
- 100 A
- Electrical endurance (switching cycles) / at AC-1 / at 380/415 V / at 50/60 Hz:
- 9000
- Electrical endurance (switching cycles) / at AC-1 / at 690 V / at 50/60 Hz:
- 5000
- Frame:
- 150A
- Height:
- 198
- Interrupt Rating:
- WITH 35kA INTERRUPTION RATING
- Length:
- 5.51
- Mechanical service life (switching cycles) / typical:
- 20000
- Mounting type:
- fixedmounting
- Number Of Poles:
- 4
- Product variations:
- Advancedapplications
- Protection class IP:
- IP40
- Protection class IP / on the front:
- IP40
- Reference code / acc. to DIN EN 61346-2:
- Q
- Reference code / acc. to DIN EN 81346-2:
- Q
- Setting range / Overload function L / IR can be switched on:
- No
- Short-circuit current making capacity (Icm) / at 240 V / rated value:
- 187kA
- Short-circuit current making capacity (Icm) / at 415 V / rated value:
- 121kA
- Standard:
- UL
- Sub Brand:
- 3VA
- Total disconnection time / for G-tripping / with standard characteristic / Full-scale value:
- 0.30s
- Total disconnection time / for G-tripping / with standard characteristic / initial value:
- 0.10s
- Trip Type:
- ETU330 LIG ADJUSTMENT KNOB
- Type:
- 3VA6
- Type of electrical connection / for main current circuit:
- Without
- Voltage Rating:
- 480 V
- Width: