Call Us Today: (800) 462-7733
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA61 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 100A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU556 TRIP UNIT LCD LSI GROUND ALARM. SPECIAL FEATURES WITHOUT LUGS 100 PERCENT RATED. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.

Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more information.

3VA6110-6JT41-2AA0

$5,009.11 / EA

manufacturer discounts
learn about discounts

  • $4,490.93 for $1,500.00+
  • $4,318.20 for $2,500.00+
  • $4,145.47 for $3,500.00+
Available to order

Local stock: 0
Lead time: over 7 working days

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA61 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 100A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU556 TRIP UNIT LCD LSI GROUND ALARM. SPECIAL FEATURES WITHOUT LUGS 100 PERCENT RATED. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA61 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 100A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU556 TRIP UNIT LCD LSI GROUND ALARM. SPECIAL FEATURES WITHOUT LUGS 100 PERCENT RATED. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.

150

UPC
804766307560
UNSPSC
39121601
Country of Origin
CZ
Number Of Poles:
4
Type:
3VA6
Voltage Rating:
480 V
Ambient temperature / during operation / maximum:
70
Ambient temperature / during operation / minimum:
-25
Ambient temperature / during storage / maximum:
80
Arrangement of electrical connectors / for main current circuit:
Withoutconnection
Connection:
punched copper bar without any lug
Current Rating:
100 A
Electrical endurance (switching cycles) / at AC-1 / at 380/415 V / at 50/60 Hz:
9000
Electrical endurance (switching cycles) / at AC-1 / at 690 V / at 50/60 Hz:
5000
Frame:
150A
Height:
198
Interrupt Rating:
WITH 65kA INTERRUPTION RATING
Length:
5.51
Mechanical service life (switching cycles) / typical:
20000
Mounting type:
fixedmounting
Number Of Poles:
4
Product variations:
Advancedapplications
Protection class IP:
IP40
Protection class IP / on the front:
IP40
Reference code / acc. to DIN EN 61346-2:
Q
Reference code / acc. to DIN EN 81346-2:
Q
Setting range / Overload function L / I**4tI**2t can be changed over:
No
Setting range / Overload function L / Setting current IR / Factor:
xIn
Setting range / Overload function L / Setting current IR / Factor of grading:
Unit
Short-circuit current making capacity (Icm) / at 240 V / rated value:
242kA
Short-circuit current making capacity (Icm) / at 415 V / rated value:
187kA
Standard:
UL
Sub Brand:
3VA
Trip Type:
ETU556 LSI(G) LCD
Type:
3VA6
Type of electrical connection / for main current circuit:
Without
Voltage Rating:
480 V
Width:
140
version / Overcurrent release / Adjustability / Overload function L:
Yes

Recently Viewed

  • placeholder image

    3VA6110-6JT41-2AA0

    SIEMENS INDUSTRY, INC.
    SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA61 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 100A 4-POLE (22KA...
    See more details
  • placeholder image

    R1GWL04-A930-WT

    W.A.C. LIGHTING COMPANY
    Unfortunately, we do not have a description available for R1GWL04-A930-WT. Please call (800) 462-7...
    See more details
  • placeholder image

    RLET-P351WW-15-3590-F-WHWH

    JESCO LIGHTING GROUP
    RECESSED LED - 3 1/2" RD - 15W - 3500K / 90CRI - WALLWASH M - WHITE REFL / WHITE TRIM
    See more details
  • placeholder image

    B11-5-E12-930-F-C

    RAB LIGHTING
    FILAMENT B11 CLEAR 5.5W 60W-Equivalent 600LM, Base E26, CRI90 3000K
    See more details
  • placeholder image

    3RT1056-6AB36-0UA0

    SIEMENS INDUSTRY, INC.
    NEMA size 4 convent. operating mechanism bar connections 3-pole, size s6 auxiliary contacts 2NO+2NC AC/DC operation uc 23...26 v contactor, 100 hp 460...
    See more details

ADDED TO CART