SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA61 FRAME WITH VERY HIGH (CLASS C) BREAKING CAPACITY. 100A 3-POLE (35KAIC AT 600V) (100KAIC AT 480V). ETU556 TRIP UNIT LCD LSI GROUND ALARM. SPECIAL FEATURES WITHOUT LUGS. DIMENSIONS (W x H x D) IN 4.1 x 7.8 x 4.2.
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA61 FRAME WITH VERY HIGH (CLASS C) BREAKING CAPACITY. 100A 3-POLE (35KAIC AT 600V) (100KAIC AT 480V). ETU556 TRIP UNIT LCD LSI GROUND ALARM. SPECIAL FEATURES WITHOUT LUGS. DIMENSIONS (W x H x D) IN 4.1 x 7.8 x 4.2.
150
- UPC
- 804766307553
- UNSPSC
- 39121601
- Country of Origin
- CZ
- Number Of Poles:
- 3
- Type:
- 3VA6
- Voltage Rating:
- 480 V
- Connection:
- punched copper bar without any lug
- Current Rating:
- 100 A
- Depth:
- 86
- Design of the operating mechanism:
- togglehandle
- Design of the overcurrent release:
- ETU556
- Design of the product:
- Systemprotection
- Frame:
- 150A
- Height:
- 198
- Interrupt Rating:
- WITH 100kA INTERRUPTION RATING
- Length:
- 4.13
- Number Of Poles:
- 3
- Power loss [W] / maximum:
- 13
- Product component / adjusting knob:
- No
- Product designation:
- Molded-casecircuitbreaker
- Product designation / according to UL file:
- CDAE
- Product function / communication function:
- Yes
- Product function / other measurement function:
- No
- Protective function of the overcurrent release:
- LSI
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / max:
- 0.8
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / minimum:
- 0.05
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (on) / max:
- 0.8
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (on) / minimum:
- 0.05
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / minimum:
- 0.2
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / minimum:
- 0.2
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / minimum:
- 1.5
- Short-circuit current making capacity (Icm) / at 690 V / rated value:
- 3.80kA
- Simaris relevant:
- -
- Standard:
- UL
- Sub Brand:
- 3VA
- Suitability for use:
- systemprotection
- Trip Type:
- ETU556 LSI(G) LCD
- Type:
- 3VA6
- Voltage Rating:
- 480 V
- Width:
- 105
- circuit-breaker / Design:
- 3VA6
- product brand name:
- SENTRON