Call Us Today: (800) 462-7733
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA61 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 150A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU560 TRIP UNIT LCD LSIG. SPECIAL FEATURES WITHOUT LUGS. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.

Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more information.

3VA6115-6JQ41-0AA0

$5,844.83 / EA

manufacturer discounts
learn about discounts

  • $5,240.20 for $1,500.00+
  • $5,038.65 for $2,500.00+
  • $4,837.10 for $3,500.00+
Available to order

Local stock: 0
Lead time: over 7 working days

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA61 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 150A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU560 TRIP UNIT LCD LSIG. SPECIAL FEATURES WITHOUT LUGS. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA61 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 150A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU560 TRIP UNIT LCD LSIG. SPECIAL FEATURES WITHOUT LUGS. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.

150

UPC
804766305177
UNSPSC
39121601
Country of Origin
CZ
Number Of Poles:
4
Type:
3VA6
Voltage Rating:
480 V
Ambient temperature / during storage / minimum:
-40
Breaking capacity current / at AC / at 240 V / acc. to UL 489 / rated value:
100
Connection:
punched copper bar without any lug
Current Rating:
150 A
Depth [in]:
3.4
Frame:
150A
Height:
198
Height [in]:
7.8
Interrupt Rating:
WITH 65kA INTERRUPTION RATING
Length:
5.51
Maximum short-circuit current breaking capacity (Icu) / at 690 V / rated value:
2.5
N-Leiterschutz N / Einstellparameter Strom InN / Werteliste:
0.2-1;0
Number Of Poles:
4
Operating current / at 55 °C / rated value:
143
Operating current / at 60 °C / rated value:
135
Product function / Ground fault protection:
Yes
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / max:
1
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / max:
1
Setting range / Overload function L / Delay time tR / I**2t characteristic curve / max:
20
Setting range / Overload function L / Setting current IR / max:
1
Setting range / Short-circuit function, instantaneous I / Setting current Ii / max:
10
Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / max:
10
Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / max:
10
Setting range / Short-circuit function, short-time delay / can be switched on/off:
No
Standard:
UL
Sub Brand:
3VA
Trip Type:
ETU560 LSIG LCD
Type:
3VA6
Voltage Rating:
480 V
Width:
140
Width [in]:
5.5

Recently Viewed

  • placeholder image

    3VA6115-6JQ41-0AA0

    SIEMENS INDUSTRY, INC.
    SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA61 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 150A 4-POLE (22KA...
    See more details
  • placeholder image

    124432-SKT-07-SS0020

    HUBBARDTON FORGE
    Unfortunately, we do not have a description available for 124432-SKT-07-SS0020. Please call (800)...
    See more details
  • placeholder image

    R1GDT12-S927-HZBK

    W.A.C. LIGHTING COMPANY
    Unfortunately, we do not have a description available for R1GDT12-S927-HZBK. Please call (800) 462...
    See more details
  • placeholder image

    3VA5125-4ED32-1AA0

    SIEMENS INDUSTRY, INC.
    SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH THERMAL - MAGNETIC TRIP UNIT. 3VA51 FRAME WITH STANDARD (CLASS S) BREAKING CAPACITY. 25A 3...
    See more details
  • placeholder image

    NUTP13-W4-4-12-930/HW

    NORA LIGHTING
    Unfortunately, we do not have a description available for NUTP13-W4-4-12-930/HW. Please call (800)...
    See more details

ADDED TO CART