SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA61 FRAME WITH VERY HIGH (CLASS C) BREAKING CAPACITY. 150A 4-POLE (35KAIC AT 600V) (100KAIC AT 480V). ETU320 TRIP UNIT LI. SPECIAL FEATURES WITHOUT LUGS 100 PERCENT RATED. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA61 FRAME WITH VERY HIGH (CLASS C) BREAKING CAPACITY. 150A 4-POLE (35KAIC AT 600V) (100KAIC AT 480V). ETU320 TRIP UNIT LI. SPECIAL FEATURES WITHOUT LUGS 100 PERCENT RATED. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.
150
- UPC
- 804766304965
- UNSPSC
- 39121601
- Country of Origin
- CZ
- Number Of Poles:
- 4
- Type:
- 3VA6
- Voltage Rating:
- 480 V
- Adjustable pick-up value current / of instantaneous short-circuit trip unit / Full-scale value:
- 1500
- Adjustable pick-up value current / of instantaneous short-circuit trip unit / initial value:
- 225
- Adjustable pick-up value current / of the current-dependent overload release / Full-scale value:
- 150
- Adjustable pick-up value current / of the current-dependent overload release / initial value:
- 60
- Arrangement of electrical connectors / for main current circuit:
- Withoutconnection
- Connection:
- punched copper bar without any lug
- Current Rating:
- 150 A
- Frame:
- 150A
- Ground fault monitoring version:
- Without
- Height:
- 198
- Insulation voltage / rated value:
- 600
- Interrupt Rating:
- WITH 100kA INTERRUPTION RATING
- Length:
- 5.51
- Maximum short-circuit current breaking capacity (Icu) / at 240 V / rated value:
- 150
- Maximum short-circuit current breaking capacity (Icu) / at 415 V / rated value:
- 110
- Mounting type:
- fixedmounting
- Number Of Poles:
- 4
- Operating current / at 65 °C / rated value:
- 133
- Operating voltage / at AC / at 50/60 Hz / rated value:
- 600
- Operational short-circuit current breaking capacity (Ics) / at 240 V / rated value:
- 150kA
- Operational short-circuit current breaking capacity (Ics) / at 415 V / rated value:
- 110kA
- Operational short-circuit current breaking capacity (Ics) / at 690 V / rated value:
- 2.5
- Power loss [W] / for rated value of the current / at AC / in hot operating state / per pole:
- 9.67
- Product variations:
- Advancedapplications
- Reference code / acc. to DIN EN 61346-2:
- Q
- Setting range / Overload function L / IR can be switched on:
- No
- Standard:
- UL
- Sub Brand:
- 3VA
- Switching capacity class of the circuit breaker:
- C
- Trip Type:
- ETU320 LI ADJUSTMENT KNOB
- Type:
- 3VA6
- Type of electrical connection / for main current circuit:
- Without
- Voltage Rating:
- 480 V
- Width:
- 140