SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA61 FRAME WITH MEDIUM (CLASS M) BREAKING CAPACITY. 40A 4-POLE (18KAIC AT 600V) (35KAIC AT 480V). ETU830 TRIP UNIT LCD LIG WITH METERING. SPECIAL FEATURES WITHOUT LUGS 100 PERCENT RATED. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.

Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more information.

3VA6140-5KM41-2AA0

$4,766.66 / EA

manufacturer discounts
learn about discounts

  • $4,273.56 for $1,500.00+
  • $4,109.19 for $2,500.00+
  • $3,944.82 for $3,500.00+
Available to order

Local stock: 0
Lead time: over 7 working days

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA61 FRAME WITH MEDIUM (CLASS M) BREAKING CAPACITY. 40A 4-POLE (18KAIC AT 600V) (35KAIC AT 480V). ETU830 TRIP UNIT LCD LIG WITH METERING. SPECIAL FEATURES WITHOUT LUGS 100 PERCENT RATED. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA61 FRAME WITH MEDIUM (CLASS M) BREAKING CAPACITY. 40A 4-POLE (18KAIC AT 600V) (35KAIC AT 480V). ETU830 TRIP UNIT LCD LIG WITH METERING. SPECIAL FEATURES WITHOUT LUGS 100 PERCENT RATED. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.

150

UPC
804766304002
UNSPSC
39121601
Country of Origin
CZ
Number Of Poles:
4
Type:
3VA6
Voltage Rating:
480 V
Ambient temperature / during operation / maximum:
70
Ambient temperature / during operation / minimum:
-25
Ambient temperature / during storage / maximum:
80
Arrangement of electrical connectors / for main current circuit:
Withoutconnection
Connection:
punched copper bar without any lug
Current Rating:
40A
Electrical endurance (switching cycles) / at AC-1 / at 380/415 V / at 50/60 Hz:
9000
Electrical endurance (switching cycles) / at AC-1 / at 690 V / at 50/60 Hz:
5000
Frame:
150A
Height:
198
Interrupt Rating:
WITH 35kA INTERRUPTION RATING
Length:
5.51
Mechanical service life (switching cycles) / typical:
20000
Mounting type:
fixedmounting
Number Of Poles:
4
Product variations:
Advancedapplications
Protection class IP:
IP40
Protection class IP / on the front:
IP40
Reference code / acc. to DIN EN 61346-2:
Q
Reference code / acc. to DIN EN 81346-2:
Q
Setting range / Overload function L / I**4tI**2t can be changed over:
No
Setting range / Overload function L / IR can be switched on:
No
Setting range / Overload function L / Setting current IR / Factor:
xIn
Short-circuit current making capacity (Icm) / at 240 V / rated value:
187kA
Short-circuit current making capacity (Icm) / at 415 V / rated value:
121kA
Standard:
UL
Sub Brand:
3VA
Trip Type:
ETU830 LIG LCD
Type:
3VA6
Type of electrical connection / for main current circuit:
Without
Voltage Rating:
480 V
Width:
140
version / Overcurrent release / Adjustability / Overload function L:
Yes

Recently Viewed

  • placeholder image

    3VA6140-5KM41-2AA0

    SIEMENS INDUSTRY, INC.
    SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA61 FRAME WITH MEDIUM (CLASS M) BREAKING CAPACITY. 40A 4-POLE (18K...
    See more details
  • placeholder image

    3RE41215CA154TB0

    SIEMENS INDUSTRY, INC.
    Non-reversing motor starter, Frame size 00, H2 UL horsepower rating Hp@VAC, 1.5@208, 2@230, 3@460, 5@575, Solid-state overload relay, Selectable Trip...
    See more details
  • placeholder image

    ML13220-W-3090-TL-WB

    JESCO LIGHTING GROUP
    3 LIGHT 277V, LED UNIT: (2) 20W, INPUT VOLTAGE: 2-270 VAC 10V/TRIAC/ELV DIMMABLE
    See more details
  • placeholder image

    ML11220-N-4090-TL-AW

    JESCO LIGHTING GROUP
    1 LIGHT 277 V, LED UNIT: (1) 20W, INPUT VOLTAGE: 2-270 VAC 10V/TRIAC/ELV DIMMABLE
    See more details
  • placeholder image

    R3ARWT-A840-HZWT

    W.A.C. LIGHTING COMPANY
    3IN WALL WASH RND TRIM CRI85 4000K
    See more details

ADDED TO CART