Call Us Today: (800) 462-7733
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA61 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 40A 3-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU820 TRIP UNIT LCD LI WITH METERING. SPECIAL FEATURES WITHOUT LUGS. DIMENSIONS (W x H x D) IN 4.1 x 7.8 x 4.2.

Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more information.

3VA6140-6KL31-0AA0

$3,603.89 / EA

manufacturer discounts
learn about discounts

  • $3,231.07 for $1,500.00+
  • $3,106.80 for $2,500.00+
  • $2,982.53 for $3,500.00+
Available to order

Local stock: 0
Lead time: over 7 working days

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA61 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 40A 3-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU820 TRIP UNIT LCD LI WITH METERING. SPECIAL FEATURES WITHOUT LUGS. DIMENSIONS (W x H x D) IN 4.1 x 7.8 x 4.2.

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA61 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 40A 3-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU820 TRIP UNIT LCD LI WITH METERING. SPECIAL FEATURES WITHOUT LUGS. DIMENSIONS (W x H x D) IN 4.1 x 7.8 x 4.2.

150

UPC
804766303715
UNSPSC
39121601
Country of Origin
CZ
Number Of Poles:
3
Type:
3VA6
Voltage Rating:
480 V
Adjustable pick-up value current / of the current-dependent overload release / initial value:
15
Connection:
punched copper bar without any lug
Continuous current / rated value:
40
Continuous current / rated value / maximum:
150.0A
Current Rating:
40A
Frame:
150A
Ground fault monitoring version:
Without
Height:
198
Insulation voltage / rated value:
600
Interrupt Rating:
WITH 65kA INTERRUPTION RATING
Length:
4.13
Maximum short-circuit current breaking capacity (Icu) / at 240 V / rated value:
110
Maximum short-circuit current breaking capacity (Icu) / at 415 V / rated value:
85
Number Of Poles:
3
Operating current / at 40 °C / rated value:
40
Operating current / at 45 °C / rated value:
40
Operating current / at 50 °C / rated value:
40
Operating current / at 65 °C / rated value:
40
Operating current / at 70 °C / rated value:
40
Operating voltage / at AC / at 50/60 Hz / rated value:
600
Operational short-circuit current breaking capacity (Ics) / at 415 V / rated value:
85kA
Operational short-circuit current breaking capacity (Ics) / at 690 V / rated value:
2.5
Overcurrent release / Protective functions:
LI
Power loss [W] / for rated value of the current / at AC / in hot operating state / per pole:
0.8
Product component / display:
Yes
Product extension / optional / motor drive:
Yes
Product feature / for neutral conductors / upgradeable/retrofittable / Short-circuit and overload proof:
No
Product function / Intrinsic device protection:
Yes
Standard:
UL
Sub Brand:
3VA
Switching capacity class of the circuit breaker:
H
Trip Type:
ETU820 LI LCD
Type:
3VA6
Type of the driving mechanism / motor drive:
No
Voltage Rating:
480 V
Width:
105

Recently Viewed

  • placeholder image

    3VA6140-6KL31-0AA0

    SIEMENS INDUSTRY, INC.
    SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA61 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 40A 3-POLE (22KAI...
    See more details
  • placeholder image

    3VA5240-6ED31-1AA0

    SIEMENS INDUSTRY, INC.
    SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH THERMAL - MAGNETIC TRIP UNIT. 3VA52 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 40A 3-POL...
    See more details
  • placeholder image

    3VA5190-6ED56-0AA0

    SIEMENS INDUSTRY, INC.
    UL Step 2
    See more details
  • placeholder image

    750120-05-10-LK-M3

    HUBBARDTON FORGE
    Unfortunately, we do not have a description available for 750120-05-10-LK-M3. Please call (800) 46...
    See more details
  • placeholder image

    MO-1023N-840-WT

    W.A.C. LIGHTING COMPANY
    EXTERMINATOR II - 23W 4000K NFL CRI85
    See more details

ADDED TO CART