SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA61 FRAME WITH EXTREMELY HIGH (CLASS L) BREAKING CAPACITY. 40A 3-POLE (50KAIC AT 600V) (150KAIC AT 480V). ETU560 TRIP UNIT LCD LSIG. SPECIAL FEATURES WITHOUT LUGS 100 PERCENT RATED. DIMENSIONS (W x H x D) IN 4.1 x 7.8 x 4.2.
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA61 FRAME WITH EXTREMELY HIGH (CLASS L) BREAKING CAPACITY. 40A 3-POLE (50KAIC AT 600V) (150KAIC AT 480V). ETU560 TRIP UNIT LCD LSIG. SPECIAL FEATURES WITHOUT LUGS 100 PERCENT RATED. DIMENSIONS (W x H x D) IN 4.1 x 7.8 x 4.2.
150
- UPC
- 804766303029
- UNSPSC
- 39121601
- Country of Origin
- CZ
- Number Of Poles:
- 3
- Type:
- 3VA6
- Voltage Rating:
- 480 V
- Ambient temperature / during operation / maximum:
- 70
- Ambient temperature / during operation / minimum:
- -25
- Ambient temperature / during storage / maximum:
- 80
- Connection:
- punched copper bar without any lug
- Current Rating:
- 40A
- Electrical endurance (switching cycles) / at AC-1 / at 380/415 V / at 50/60 Hz:
- 9000
- Electrical endurance (switching cycles) / at AC-1 / at 690 V / at 50/60 Hz:
- 5000
- Frame:
- 150A
- Height:
- 7.8 in
- Interrupt Rating:
- WITH 150kA INTERRUPTION RATING
- Length:
- 4.13
- Mechanical service life (switching cycles) / typical:
- 20000
- Number Of Poles:
- 3
- Reference code / acc. to DIN EN 81346-2:
- Q
- Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Factor:
- s
- Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Factor of grading:
- Settingtable
- Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Grading:
- 0.5-25;0.1
- Setting range / Overload function L / I**4tI**2t can be changed over:
- No
- Setting range / Overload function L / Setting current IR / Factor:
- xIn
- Setting range / Overload function L / Setting current IR / Factor of grading:
- Unit
- Setting range / Overload function L / Setting current IR / Grading:
- 0.4-1;0
- Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / Factor:
- xIn
- Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / Factor of grading:
- Unit
- Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / Grading:
- 0.6-10;0
- Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / can be switched on/off:
- Yes
- Short-circuit current making capacity (Icm) / at 240 V / rated value:
- 440kA
- Short-circuit current making capacity (Icm) / at 415 V / rated value:
- 330kA
- Standard:
- UL
- Sub Brand:
- 3VA
- Trip Type:
- ETU560 LSIG LCD
- Trip class / of the L-trip / with I2t characteristic / Full-scale value:
- 25
- Trip class / of the L-trip / with I2t characteristic / initial value:
- 0.5
- Type:
- 3VA6
- Voltage Rating:
- 480 V
- Width:
- 4.21
- version / Overcurrent release / Adjustability / Overload function L:
- Yes