SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA61 FRAME WITH EXTREMELY HIGH (CLASS L) BREAKING CAPACITY. 40A 4-POLE (50KAIC AT 600V) (150KAIC AT 480V). ETU856 TRIP UNIT LCD LSI GROUNG ALARM WITH METERING. SPECIAL FEATURES WITHOUT LUGS. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA61 FRAME WITH EXTREMELY HIGH (CLASS L) BREAKING CAPACITY. 40A 4-POLE (50KAIC AT 600V) (150KAIC AT 480V). ETU856 TRIP UNIT LCD LSI GROUNG ALARM WITH METERING. SPECIAL FEATURES WITHOUT LUGS. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.
150
- UPC
- 804766307652
- UNSPSC
- 39121601
- Country of Origin
- CZ
- Number Of Poles:
- 4
- Type:
- 3VA6
- Voltage Rating:
- 480 V
- Ambient temperature / during storage / minimum:
- -40
- Connection:
- punched copper bar without any lug
- Current Rating:
- 40A
- Design of the product:
- Systemprotection
- Frame:
- 150A
- Height:
- 198
- Interrupt Rating:
- WITH 150kA INTERRUPTION RATING
- Length:
- 5.51
- Maximum short-circuit current breaking capacity (Icu) / at 690 V / rated value:
- 2.5
- Number Of Poles:
- 4
- Operating current / at 55 °C / rated value:
- 40
- Product designation:
- Molded-casecircuitbreaker
- Product designation / according to UL file:
- LDAE
- Product function / Ground fault protection:
- No
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / max:
- 1
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / max:
- 1
- Setting range / Overload function L / Delay time tR / I**2t characteristic curve / max:
- 25
- Setting range / Overload function L / Setting current IR / max:
- 1
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / max:
- 12
- Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / max:
- 10
- Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / max:
- 10
- Setting range / Short-circuit function, short-time delay / can be switched on/off:
- No
- Simaris relevant:
- -
- Standard:
- UL
- Sub Brand:
- 3VA
- Suitability for use:
- systemprotection
- Trip Type:
- ETU856 LSI(G) LCD
- Type:
- 3VA6
- Voltage Rating:
- 480 V
- Width:
- 140
- product brand name:
- SENTRON