Call Us Today: (800) 462-7733
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA62 FRAME WITH MEDIUM (CLASS H) BREAKING CAPACITY. 100A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU830 TRIP UNIT LCD LIG WITH METERING. SPECIAL FEATURES WITHOUT LUGS. 100 PERCENT RATED. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.

Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more information.

3VA6210-6KM41-2AA0

$8,131.72 / EA

manufacturer discounts
learn about discounts

  • $7,290.50 for $1,500.00+
  • $7,010.10 for $2,500.00+
  • $6,729.70 for $3,500.00+
Available to order

Local stock: 0
Lead time: over 7 working days

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA62 FRAME WITH MEDIUM (CLASS H) BREAKING CAPACITY. 100A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU830 TRIP UNIT LCD LIG WITH METERING. SPECIAL FEATURES WITHOUT LUGS. 100 PERCENT RATED. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA62 FRAME WITH MEDIUM (CLASS H) BREAKING CAPACITY. 100A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU830 TRIP UNIT LCD LIG WITH METERING. SPECIAL FEATURES WITHOUT LUGS. 100 PERCENT RATED. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.

150

UPC
804766311031
UNSPSC
39121601
Country of Origin
CZ
Number Of Poles:
4
Type:
3VA6
Voltage Rating:
480 V
Adjustable pick-up value current / for G-tripping / with standard characteristic / Full-scale value:
100.00A
Adjustable pick-up value current / for G-tripping / with standard characteristic / initial value:
20.00A
Adjustable pick-up value current / of instantaneous short-circuit trip unit / initial value:
150
Ambient temperature / during operation / maximum:
70
Ambient temperature / during operation / minimum:
-25
Ambient temperature / during storage / maximum:
80
Arrangement of electrical connectors / for main current circuit:
Withoutconnection
Connection:
punched copper bar without any lug
Current Rating:
100 A
Electrical endurance (switching cycles) / at AC-1 / at 380/415 V / at 50/60 Hz:
6000
Electrical endurance (switching cycles) / at AC-1 / at 690 V / at 50/60 Hz:
3000
Frame:
250A
Height:
198
Interrupt Rating:
WITH 65kA INTERRUPTION RATING
Length:
5.51
Mechanical service life (switching cycles) / typical:
20000
Mounting type:
fixedmounting
Number Of Poles:
4
Product variations:
Advancedapplications
Protection class IP:
IP40
Protection class IP / on the front:
IP40
Reference code / acc. to DIN EN 61346-2:
Q
Reference code / acc. to DIN EN 81346-2:
Q
Setting range / Overload function L / IR can be switched on:
No
Standard:
UL
Sub Brand:
3VA
Total disconnection time / for G-tripping / with standard characteristic / Full-scale value:
0.80s
Total disconnection time / for G-tripping / with standard characteristic / initial value:
0.05s
Trip Type:
ETU830 LIG LCD
Type:
3VA6
Type of electrical connection / for main current circuit:
Without
Voltage Rating:
480 V
Width:
140

Recently Viewed

  • placeholder image

    3VA6210-6KM41-2AA0

    SIEMENS INDUSTRY, INC.
    SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA62 FRAME WITH MEDIUM (CLASS H) BREAKING CAPACITY. 100A 4-POLE (22...
    See more details
  • placeholder image

    123-P-P&S

    LEGRAND/PASS & SEYMOUR
    Unfortunately, we do not have a description available for 123-P-P&S. Please call (800) 462-7733 See more details
  • placeholder image

    V1800W12C/RC

    ELEGANT LIGHTING
    Unfortunately, we do not have a description available for V1800W12C/RC. Please call (800) 462-7733...
    See more details
  • placeholder image

    LSQ-1-4-U-40-W-I

    NICOR LIGHTING
    Unfortunately, we do not have a description available for LSQ-1-4-U-40-W-I. Please call (800) 462-...
    See more details
  • placeholder image

    LHB80W-850-EX39

    TOPAZ LIGHTING CORP.
    Unfortunately, we do not have a description available for LHB80W-850-EX39. Please call (800) 462-7...
    See more details

ADDED TO CART