Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more
information.
$12,292.58 / EA
manufacturer discounts
learn about discounts
- $11,020.93 for $1,500.00+
- $10,597.05 for $2,500.00+
- $10,173.17 for $3,500.00+
Local stock: 0
Lead time:
over 7 working days
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA62 FRAME WITH HIGH (CLASS L) BREAKING CAPACITY. 100A 4-POLE (50KAIC AT 600V) (150KAIC AT 480V). ETU860 TRIP UNIT LCD LSIG WITH METERING. SPECIAL FEATURES WITHOUT LUGS.. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA62 FRAME WITH HIGH (CLASS L) BREAKING CAPACITY. 100A 4-POLE (50KAIC AT 600V) (150KAIC AT 480V). ETU860 TRIP UNIT LCD LSIG WITH METERING. SPECIAL FEATURES WITHOUT LUGS.. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.
150
- UPC
- 804766310249
- UNSPSC
- 39121601
- Country of Origin
- CZ
- Number Of Poles:
- 4
- Type:
- 3VA6
- Voltage Rating:
- 480 V
- Adjustable delay time / of S-trip / with standard characteristic / initial value:
- 0.05s
- Adjustable pick-up value current / for G-tripping / with standard characteristic / Full-scale value:
- 100.00A
- Adjustable pick-up value current / for G-tripping / with standard characteristic / initial value:
- 20.00A
- Adjustable pick-up value current / of instantaneous short-circuit trip unit / Full-scale value:
- 1200
- Adjustable pick-up value current / of instantaneous short-circuit trip unit / initial value:
- 150
- Adjustable pick-up value current / of the current-dependent overload release / Full-scale value:
- 100
- Adjustable pick-up value current / of the current-dependent overload release / initial value:
- 40
- Adjustable pick-up value current / of the short-time delayed short-circuit release / Full-scale value:
- 1000.00A
- Adjustable pick-up value current / of the short-time delayed short-circuit release / initial value:
- 60.00A
- Connection:
- punched copper bar without any lug
- Continuous current / rated value / maximum:
- 250.0A
- Current Rating:
- 100 A
- Frame:
- 250A
- Ground fault monitoring version:
- SummationcurrentformationL+N-conductor
- Height:
- 198
- Insulation voltage / rated value:
- 600
- Interrupt Rating:
- WITH 150kA INTERRUPTION RATING
- Length:
- 5.51
- Maximum short-circuit current breaking capacity (Icu) / at 240 V / rated value:
- 200
- Maximum short-circuit current breaking capacity (Icu) / at 415 V / rated value:
- 150
- Number Of Poles:
- 4
- Operating current / at 45 °C / rated value:
- 100
- Operating current / at 65 °C / rated value:
- 100
- Operating voltage / at AC / at 50/60 Hz / rated value:
- 600
- Operational short-circuit current breaking capacity (Ics) / at 240 V / rated value:
- 200kA
- Operational short-circuit current breaking capacity (Ics) / at 415 V / rated value:
- 150kA
- Operational short-circuit current breaking capacity (Ics) / at 690 V / rated value:
- 3
- Power loss [W] / for rated value of the current / at AC / in hot operating state / per pole:
- 2.23
- Product feature / for neutral conductors / upgradeable/retrofittable / Short-circuit and overload proof:
- No
- Standard:
- UL
- Sub Brand:
- 3VA
- Switching capacity class of the circuit breaker:
- L
- Trip Type:
- ETU860 LSIG LCD
- Type:
- 3VA6
- Voltage Rating:
- 480 V
- Width:
- 140