SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA62 FRAME WITH VERY HIGH (CLASS E) BREAKING CAPACITY. 250A 4-POLE (100KAIC AT 600V) (200KAIC AT 480V). ETU330 TRIP UNIT LIG. SPECIAL FEATURES WITHOUT LUGS.. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA62 FRAME WITH VERY HIGH (CLASS E) BREAKING CAPACITY. 250A 4-POLE (100KAIC AT 600V) (200KAIC AT 480V). ETU330 TRIP UNIT LIG. SPECIAL FEATURES WITHOUT LUGS.. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.
150
- UPC
- 804766977862
- Number Of Poles:
- 4
- Ambient temperature / during storage / minimum:
- -40
- Breaking capacity current / at AC / at 480 V / acc. to UL 489 / rated value:
- 200
- Breaking capacity current / at AC / at 600 V / acc. to UL 489 / rated value:
- 100
- Certificate of suitability / as approval for NAVAL (no combat vessels) / Supplement SB:
- Yes
- Depth:
- 86
- Depth [in]:
- 3.4
- Design of the load switch / acc. to UL 489 / Heating, Air Conditioning, and Refrigeration circuit breaker (HACR Type):
- Yes
- Electrical endurance (switching cycles) / at 480 V / at 50/60 Hz:
- 6000
- Electrical endurance (switching cycles) / at 600 V / at 50/60 Hz:
- 7500
- Height:
- 198
- Height [in]:
- 7.8
- Marking / of circuit breaker / acc. to UL 489 / 100%-rated breaker:
- No
- Maximum short-circuit current breaking capacity (Icu) / at 690 V / rated value:
- 3
- N-Leiter Schutz / einstellbar:
- Yes
- N-Leiterschutz N / Einstellparameter Strom InN / Einheit der Werteliste:
- Unit
- N-Leiterschutz N / Einstellparameter Strom InN / Format der Werteliste:
- xIr
- N-Leiterschutz N / Einstellparameter Strom InN / Werteliste:
- 0.5;1
- N-leiter-schutz / Ein-/Ausschaltbar:
- Yes
- Number Of Poles:
- 4
- Operating current / at 55 °C / rated value:
- 250
- Operating current / at 60 °C / rated value:
- 250
- Power loss [W] / maximum:
- 42
- Product component / adjusting knob:
- Yes
- Product function / Ground fault protection:
- Yes
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / max:
- 0.3
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / minimum:
- 0.1
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Grading:
- 0.2;0.4;0.6;0.8;1
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / max:
- 1
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / minimum:
- 0.2
- Setting range / Overload function L / Delay time tR / I**2t characteristic curve / max:
- 13
- Setting range / Overload function L / Delay time tR / I**2t characteristic curve / min:
- 0.5
- Setting range / Overload function L / Setting current IR / max:
- 1
- Setting range / Overload function L / Setting current IR / min:
- 0.4
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / max:
- 10
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / minimum:
- 1.5
- Width:
- 140
- Width [in]:
- 5.5