Call Us Today: (800) 462-7733
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA62 FRAME WITH VERY HIGH (CLASS E) BREAKING CAPACITY. 250A 3-POLE (100KAIC AT 600V) (200KAIC AT 480V). ETU856 TRIP UNIT LCD LSI GROUNG ALARM WITH METERING.SPECIAL FEATURES WITHOUT LUGS.. DIMENSIONS (W x H x D) IN 4.1 x 7.8 x 4.2.

Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more information.

3VA6225-0KT31-0AA0

$12,519.13 / EA

manufacturer discounts
learn about discounts

  • $11,224.04 for $1,500.00+
  • $10,792.35 for $2,500.00+
  • $10,360.66 for $3,500.00+
Available to order

Local stock: 0
Lead time: over 7 working days

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA62 FRAME WITH VERY HIGH (CLASS E) BREAKING CAPACITY. 250A 3-POLE (100KAIC AT 600V) (200KAIC AT 480V). ETU856 TRIP UNIT LCD LSI GROUNG ALARM WITH METERING.SPECIAL FEATURES WITHOUT LUGS.. DIMENSIONS (W x H x D) IN 4.1 x 7.8 x 4.2.

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA62 FRAME WITH VERY HIGH (CLASS E) BREAKING CAPACITY. 250A 3-POLE (100KAIC AT 600V) (200KAIC AT 480V). ETU856 TRIP UNIT LCD LSI GROUNG ALARM WITH METERING.SPECIAL FEATURES WITHOUT LUGS.. DIMENSIONS (W x H x D) IN 4.1 x 7.8 x 4.2.

150

UPC
804766977916
Number Of Poles:
3
Adjustable delay time / for G-tripping / with I2t characteristic / Full-scale value:
0.80s
Adjustable delay time / for G-tripping / with I2t characteristic / initial value:
0.05s
Adjustable delay time / of S-trip / with I2t characteristic / Full-scale value:
0.50s
Adjustable delay time / of S-trip / with I2t characteristic / initial value:
0.05s
Adjustable delay time / of S-trip / with standard characteristic / Full-scale value:
0.50s
Adjustable delay time / of S-trip / with standard characteristic / initial value:
0.05s
Adjustable pick-up value current / for G-tripping / with standard characteristic / Full-scale value:
250.00A
Adjustable pick-up value current / for G-tripping / with standard characteristic / initial value:
50.00A
Adjustable pick-up value current / of instantaneous short-circuit trip unit / Full-scale value:
2500
Adjustable pick-up value current / of instantaneous short-circuit trip unit / initial value:
375
Adjustable pick-up value current / of the current-dependent overload release / Full-scale value:
250
Adjustable pick-up value current / of the current-dependent overload release / initial value:
100
Adjustable pick-up value current / of the short-time delayed short-circuit release / Full-scale value:
2500.00A
Adjustable pick-up value current / of the short-time delayed short-circuit release / initial value:
150.00A
Arrangement of electrical connectors / for main current circuit:
Withoutconnection
Continuous current / rated value / maximum:
250.0A
Ground fault monitoring version:
Without
Height:
198
Insulation voltage / rated value:
800
Maximum short-circuit current breaking capacity (Icu) / at 415 V / rated value:
200
Mounting type:
fixedmounting
Number Of Poles:
3
Operating current / at 40 °C / rated value:
250
Operating current / at 45 °C / rated value:
250
Operating current / at 65 °C / rated value:
213
Operating voltage / at AC / at 50/60 Hz / rated value:
600
Operational short-circuit current breaking capacity (Ics) / at 415 V / rated value:
150kA
Operational short-circuit current breaking capacity (Ics) / at 690 V / rated value:
3
Power loss [W] / for rated value of the current / at AC / in hot operating state / per pole:
14
Product feature / for neutral conductors / upgradeable/retrofittable / Short-circuit and overload proof:
Yes
Product variations:
Advancedapplications
Setting range / Overload function L / IR can be switched on:
No
Total disconnection time / for G-tripping / with standard characteristic / Full-scale value:
0.80s
Total disconnection time / for G-tripping / with standard characteristic / initial value:
0.05s
Type of electrical connection / for main current circuit:
Without
Width:
105

Recently Viewed

  • placeholder image

    3VA6225-0KT31-0AA0

    SIEMENS INDUSTRY, INC.
    SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA62 FRAME WITH VERY HIGH (CLASS E) BREAKING CAPACITY. 250A 3-POLE...
    See more details
  • placeholder image

    3VA2125-5MQ36-0AA0

    SIEMENS INDUSTRY, INC.
    SIEMENS LOW VOLTAGE 3VA IEC MOTOR CIRCUIT PROTECTOR WITH ELECTRONIC TRIP UNIT. 3VA21 FRAME WITH MEDIUM (CLASS M) BREAKING CAPACITY. 25A 3-POLE Icu (2....
    See more details
  • placeholder image

    3VA4120-4ED34-1AA0

    SIEMENS INDUSTRY, INC.
    SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH THERMAL - MAGNETIC TRIP UNIT. 3VA41 FRAME WITH STANDARD (CLASS S) BREAKING CAPACITY. 20A 3...
    See more details
  • placeholder image

    GM4802-L18-40K-W

    DABMAR LIGHTING INC.
    Unfortunately, we do not have a description available for GM4802-L18-40K-W. Please call (800) 462-...
    See more details
  • placeholder image

    13CN9600-L-10

    HUBBARDTON FORGE
    Unfortunately, we do not have a description available for 13CN9600-L-10. Please call (800) 462-773...
    See more details

ADDED TO CART