Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more
information.
$12,519.13 / EA
manufacturer discounts
learn about discounts
- $11,224.04 for $1,500.00+
- $10,792.35 for $2,500.00+
- $10,360.66 for $3,500.00+
Local stock: 0
Lead time:
over 7 working days
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA62 FRAME WITH VERY HIGH (CLASS E) BREAKING CAPACITY. 250A 3-POLE (100KAIC AT 600V) (200KAIC AT 480V). ETU856 TRIP UNIT LCD LSI GROUNG ALARM WITH METERING.SPECIAL FEATURES WITHOUT LUGS.. DIMENSIONS (W x H x D) IN 4.1 x 7.8 x 4.2.
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA62 FRAME WITH VERY HIGH (CLASS E) BREAKING CAPACITY. 250A 3-POLE (100KAIC AT 600V) (200KAIC AT 480V). ETU856 TRIP UNIT LCD LSI GROUNG ALARM WITH METERING.SPECIAL FEATURES WITHOUT LUGS.. DIMENSIONS (W x H x D) IN 4.1 x 7.8 x 4.2.
150
- UPC
- 804766977916
- Number Of Poles:
- 3
- Adjustable delay time / for G-tripping / with I2t characteristic / Full-scale value:
- 0.80s
- Adjustable delay time / for G-tripping / with I2t characteristic / initial value:
- 0.05s
- Adjustable delay time / of S-trip / with I2t characteristic / Full-scale value:
- 0.50s
- Adjustable delay time / of S-trip / with I2t characteristic / initial value:
- 0.05s
- Adjustable delay time / of S-trip / with standard characteristic / Full-scale value:
- 0.50s
- Adjustable delay time / of S-trip / with standard characteristic / initial value:
- 0.05s
- Adjustable pick-up value current / for G-tripping / with standard characteristic / Full-scale value:
- 250.00A
- Adjustable pick-up value current / for G-tripping / with standard characteristic / initial value:
- 50.00A
- Adjustable pick-up value current / of instantaneous short-circuit trip unit / Full-scale value:
- 2500
- Adjustable pick-up value current / of instantaneous short-circuit trip unit / initial value:
- 375
- Adjustable pick-up value current / of the current-dependent overload release / Full-scale value:
- 250
- Adjustable pick-up value current / of the current-dependent overload release / initial value:
- 100
- Adjustable pick-up value current / of the short-time delayed short-circuit release / Full-scale value:
- 2500.00A
- Adjustable pick-up value current / of the short-time delayed short-circuit release / initial value:
- 150.00A
- Arrangement of electrical connectors / for main current circuit:
- Withoutconnection
- Continuous current / rated value / maximum:
- 250.0A
- Ground fault monitoring version:
- Without
- Height:
- 198
- Insulation voltage / rated value:
- 800
- Maximum short-circuit current breaking capacity (Icu) / at 415 V / rated value:
- 200
- Mounting type:
- fixedmounting
- Number Of Poles:
- 3
- Operating current / at 40 °C / rated value:
- 250
- Operating current / at 45 °C / rated value:
- 250
- Operating current / at 65 °C / rated value:
- 213
- Operating voltage / at AC / at 50/60 Hz / rated value:
- 600
- Operational short-circuit current breaking capacity (Ics) / at 415 V / rated value:
- 150kA
- Operational short-circuit current breaking capacity (Ics) / at 690 V / rated value:
- 3
- Power loss [W] / for rated value of the current / at AC / in hot operating state / per pole:
- 14
- Product feature / for neutral conductors / upgradeable/retrofittable / Short-circuit and overload proof:
- Yes
- Product variations:
- Advancedapplications
- Setting range / Overload function L / IR can be switched on:
- No
- Total disconnection time / for G-tripping / with standard characteristic / Full-scale value:
- 0.80s
- Total disconnection time / for G-tripping / with standard characteristic / initial value:
- 0.05s
- Type of electrical connection / for main current circuit:
- Without
- Width:
- 105