Call Us Today: (800) 462-7733
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA62 FRAME WITH VERY HIGH (CLASS E) BREAKING CAPACITY. 250A 4-POLE (100KAIC AT 600V) (200KAIC AT 480V). ETU856 TRIP UNIT LCD LSI GROUNG ALARM WITH METERING.SPECIAL FEATURES WITHOUT LUGS.. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.

Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more information.

3VA6225-0KT41-0AA0

$15,231.96 / EA

manufacturer discounts
learn about discounts

  • $13,656.24 for $1,500.00+
  • $13,131.00 for $2,500.00+
  • $12,605.76 for $3,500.00+
Available to order

Local stock: 0
Lead time: over 7 working days

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA62 FRAME WITH VERY HIGH (CLASS E) BREAKING CAPACITY. 250A 4-POLE (100KAIC AT 600V) (200KAIC AT 480V). ETU856 TRIP UNIT LCD LSI GROUNG ALARM WITH METERING.SPECIAL FEATURES WITHOUT LUGS.. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA62 FRAME WITH VERY HIGH (CLASS E) BREAKING CAPACITY. 250A 4-POLE (100KAIC AT 600V) (200KAIC AT 480V). ETU856 TRIP UNIT LCD LSI GROUNG ALARM WITH METERING.SPECIAL FEATURES WITHOUT LUGS.. DIMENSIONS (W x H x D) IN 5.5 x 7.8 x 4.2.

150

UPC
804766977923
Number Of Poles:
4
Height:
198
Number Of Poles:
4
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Factor:
s
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Grading:
0.05-0.8;0.01
Setting range / Earth fault function G / Ig-function can be switched on/off:
Yes
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / Factor of grading:
Unit
Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Factor:
s
Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Factor of grading:
Settingtable
Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Grading:
0.5-13;0.1
Setting range / Overload function L / I**4tI**2t can be changed over:
No
Setting range / Overload function L / Setting current IR / Factor:
xIn
Setting range / Overload function L / Setting current IR / Factor of grading:
Unit
Setting range / Overload function L / Setting current IR / Grading:
0.4-1;0
Setting range / Short-circuit function, instantaneous I / Setting current Ii / Factor:
xIn
Setting range / Short-circuit function, instantaneous I / Setting current Ii / Factor of grading:
Unit
Setting range / Short-circuit function, instantaneous I / Setting current Ii / Grading:
1.5-10;0
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (off) / Factor:
s
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (off) / Factor of grading:
Settingtable
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (off) / Grading:
0.05-0.5;0.01
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Factor:
s
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Factor of grading:
Settingtable
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Grading:
0.05-0.5;0.01
Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / Factor:
xIn
Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / Factor of grading:
Unit
Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / Grading:
0.6-10;0
Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / Factor:
xIn
Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / Factor of grading:
Unit
Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / Grading:
0.6-10;0
Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / can be switched on/off:
Yes
Setting range / ground fault function G / lg function selectable:
Yes
Short-circuit current making capacity (Icm) / at 415 V / rated value:
440kA
Trip class / of the L-trip / with I2t characteristic / Full-scale value:
13
Trip class / of the L-trip / with I2t characteristic / initial value:
0.5
Width:
140
i-trip unit / can be switched ON/OFF:
No
version / Overcurrent release / Adjustability / Overload function L:
Yes
version / Overcurrent release / Adjustability / Short-circuit function, instantaneous I:
Yes

Recently Viewed

  • placeholder image

    3VA6225-0KT41-0AA0

    SIEMENS INDUSTRY, INC.
    SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA62 FRAME WITH VERY HIGH (CLASS E) BREAKING CAPACITY. 250A 4-POLE...
    See more details
  • placeholder image

    3VA6560-6HM32-0AA0

    SIEMENS INDUSTRY, INC.
    Unfortunately, we do not have a description available for 3VA6560-6HM32-0AA0. Please call (800) 46...
    See more details
  • placeholder image

    3VA6110-7JP36-0AA0

    SIEMENS INDUSTRY, INC.
    SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA61 FRAME WITH VERY HIGH (CLASS C) BREAKING CAPACITY. 100A 3-POLE...
    See more details
  • placeholder image

    DI-120V-BW-WW-RGBW-2F-BL

    ELEMENTAL LED
    Unfortunately, we do not have a description available for DI-120V-BW-WW-RGBW-2F-BL. Please call (8...
    See more details
  • placeholder image

    124304-SKT-07-SS0053

    HUBBARDTON FORGE
    Unfortunately, we do not have a description available for 124304-SKT-07-SS0053. Please call (800)...
    See more details

ADDED TO CART