SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA63 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 250A 3-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU856 TRIP UNIT LCD LSI GROUNG ALARM WITH METERING. SPECIAL FEATURES WITHOUT LUGS 100 PERCENT RATED. DIMENSIONS (W x H x D) IN 5.4 x 9.8 x5.4.
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA63 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 250A 3-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU856 TRIP UNIT LCD LSI GROUNG ALARM WITH METERING. SPECIAL FEATURES WITHOUT LUGS 100 PERCENT RATED. DIMENSIONS (W x H x D) IN 5.4 x 9.8 x5.4.
150
- UPC
- 804766315251
- UNSPSC
- 39121601
- Country of Origin
- CZ
- Number Of Poles:
- 3
- Type:
- 3VA6
- Voltage Rating:
- 480 V
- Adjustable delay time / for G-tripping / with I2t characteristic / Full-scale value:
- 0.80s
- Adjustable delay time / for G-tripping / with I2t characteristic / initial value:
- 0.05s
- Adjustable delay time / of S-trip / with I2t characteristic / Full-scale value:
- 0.50s
- Adjustable delay time / of S-trip / with I2t characteristic / initial value:
- 0.05s
- Adjustable delay time / of S-trip / with standard characteristic / Full-scale value:
- 0.50s
- Adjustable delay time / of S-trip / with standard characteristic / initial value:
- 0.05s
- Adjustable pick-up value current / for G-tripping / with standard characteristic / Full-scale value:
- 250.00A
- Adjustable pick-up value current / for G-tripping / with standard characteristic / initial value:
- 50.00A
- Adjustable pick-up value current / of instantaneous short-circuit trip unit / Full-scale value:
- 3000
- Adjustable pick-up value current / of instantaneous short-circuit trip unit / initial value:
- 375
- Adjustable pick-up value current / of the current-dependent overload release / Full-scale value:
- 250
- Adjustable pick-up value current / of the short-time delayed short-circuit release / Full-scale value:
- 2500.00A
- Adjustable pick-up value current / of the short-time delayed short-circuit release / initial value:
- 150.00A
- Arrangement of electrical connectors / for main current circuit:
- Withoutconnection
- Connection:
- punched copper bar without any lug
- Current Rating:
- 250 A
- Frame:
- 400A
- Height:
- 248
- Interrupt Rating:
- WITH 65kA INTERRUPTION RATING
- Length:
- 5.43
- Mounting type:
- fixedmounting
- Number Of Poles:
- 3
- Operational short-circuit current breaking capacity (Ics) / at 240 V / rated value:
- 110kA
- Product variations:
- Advancedapplications
- Reference code / acc. to DIN EN 61346-2:
- Q
- Setting range / Overload function L / IR can be switched on:
- No
- Standard:
- UL
- Sub Brand:
- 3VA
- Total disconnection time / for G-tripping / with standard characteristic / Full-scale value:
- 0.80s
- Total disconnection time / for G-tripping / with standard characteristic / initial value:
- 0.05s
- Trip Type:
- ETU856 LSI(G) LCD
- Type:
- 3VA6
- Type of electrical connection / for main current circuit:
- Without
- Voltage Rating:
- 480 V
- Width: