Call Us Today: (800) 462-7733
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA63 FRAME WITH MEDIUM (CLASS M) BREAKING CAPACITY. 400A 3-POLE (18KAIC AT 600V) (35KAIC AT 480V). ETU560 TRIP UNIT LCD LSIG. SPECIAL FEATURES WITHOUT LUGS.DIMENSIONS (W x H x D) IN 5.4 x 9.8 x 5.4.

Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more information.

3VA6340-5JQ31-0AA0

$5,248.71 / EA

manufacturer discounts
learn about discounts

  • $4,705.74 for $1,500.00+
  • $4,524.75 for $2,500.00+
  • $4,343.76 for $3,500.00+
Available to order

Local stock: 0
Lead time: over 7 working days

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA63 FRAME WITH MEDIUM (CLASS M) BREAKING CAPACITY. 400A 3-POLE (18KAIC AT 600V) (35KAIC AT 480V). ETU560 TRIP UNIT LCD LSIG. SPECIAL FEATURES WITHOUT LUGS.DIMENSIONS (W x H x D) IN 5.4 x 9.8 x 5.4.

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA63 FRAME WITH MEDIUM (CLASS M) BREAKING CAPACITY. 400A 3-POLE (18KAIC AT 600V) (35KAIC AT 480V). ETU560 TRIP UNIT LCD LSIG. SPECIAL FEATURES WITHOUT LUGS.DIMENSIONS (W x H x D) IN 5.4 x 9.8 x 5.4.

150

UPC
804766313301
UNSPSC
39121601
Country of Origin
CZ
Number Of Poles:
3
Type:
3VA6
Voltage Rating:
480 V
Connection:
punched copper bar without any lug
Current Rating:
400A
Frame:
400A
Height:
9.76 in
Interrupt Rating:
WITH 35kA INTERRUPTION RATING
Length:
5.43
Number Of Poles:
3
Setting range / Earth fault function G / Ig-function can be switched on/off:
Yes
Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Factor:
s
Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Factor of grading:
Settingtable
Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Grading:
0.5-17;0.1
Setting range / Overload function L / Setting current IR / Factor of grading:
Unit
Setting range / Overload function L / Setting current IR / Grading:
0.4-1;0
Setting range / Short-circuit function, instantaneous I / Setting current Ii / Factor:
xIn
Setting range / Short-circuit function, instantaneous I / Setting current Ii / Factor of grading:
Unit
Setting range / Short-circuit function, instantaneous I / Setting current Ii / Grading:
1.5-10;0
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (off) / Factor:
s
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (off) / Factor of grading:
Settingtable
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (off) / Grading:
0.05-0.5;0.01
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Factor:
s
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Factor of grading:
Settingtable
Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / Factor:
xIn
Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / Factor of grading:
Unit
Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / Grading:
0.6-10;0
Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / Factor:
xIn
Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / Factor of grading:
Unit
Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / Grading:
0.6-10;0
Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / can be switched on/off:
Yes
Standard:
UL
Sub Brand:
3VA
Trip Type:
ETU560 LSIG LCD
Trip class / of the L-trip / with I2t characteristic / Full-scale value:
17
Trip class / of the L-trip / with I2t characteristic / initial value:
0.5
Type:
3VA6
Voltage Rating:
480 V
Width:
5.41

Recently Viewed

  • placeholder image

    3VA6340-5JQ31-0AA0

    SIEMENS INDUSTRY, INC.
    SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA63 FRAME WITH MEDIUM (CLASS M) BREAKING CAPACITY. 400A 3-POLE (18...
    See more details
  • placeholder image

    3VA6210-6KL41-0AA0

    SIEMENS INDUSTRY, INC.
    SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA62 FRAME WITH MEDIUM (CLASS H) BREAKING CAPACITY. 100A 4-POLE (22...
    See more details
  • placeholder image

    NUTP13-W6-12-927/HW

    NORA LIGHTING
    Unfortunately, we do not have a description available for NUTP13-W6-12-927/HW. Please call (800) 4...
    See more details
  • placeholder image

    3VA6610-5JT36-0AA0

    SIEMENS INDUSTRY, INC.
    SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA66 FRAME WITH MEDIUM LOW (CLASS M) BREAKING CAPACITY. 1000A 3-POL...
    See more details
  • placeholder image

    750114-20-86-LB-M1

    HUBBARDTON FORGE
    Unfortunately, we do not have a description available for 750114-20-86-LB-M1. Please call (800) 46...
    See more details

ADDED TO CART