SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA63 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 400A 3-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU860 TRIP UNIT LCD LSIG WITH METERING. SPECIAL FEATURES WITHOUT LUGS. DIMENSIONS (W x H x D) IN 5.4 x 9.8 x 5.4.

Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more information.

3VA6340-6KQ31-0AA0

$7,441.11 / EA

manufacturer discounts
learn about discounts

  • $6,671.34 for $1,500.00+
  • $6,414.75 for $2,500.00+
  • $6,158.16 for $3,500.00+
Available to order

Local stock: 0
Lead time: over 7 working days

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA63 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 400A 3-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU860 TRIP UNIT LCD LSIG WITH METERING. SPECIAL FEATURES WITHOUT LUGS. DIMENSIONS (W x H x D) IN 5.4 x 9.8 x 5.4.

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA63 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 400A 3-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU860 TRIP UNIT LCD LSIG WITH METERING. SPECIAL FEATURES WITHOUT LUGS. DIMENSIONS (W x H x D) IN 5.4 x 9.8 x 5.4.

150

UPC
804766313042
UNSPSC
39121601
Country of Origin
CZ
Number Of Poles:
3
Type:
3VA6
Voltage Rating:
480 V
Connection:
punched copper bar without any lug
Current Rating:
400A
Diken-export / tripping characteristics / Upper tolerance band:
AK_3VA6_3_400A_ETU5u8_MuHuCuL_oT
Frame:
400A
Height:
9.76 in
Interrupt Rating:
WITH 65kA INTERRUPTION RATING
Length:
5.43
N-Leiter Schutz / einstellbar:
Yes
N-Leiterschutz N / Einstellparameter Strom InN / Einheit der Werteliste:
Unit
N-Leiterschutz N / Einstellparameter Strom InN / Format der Werteliste:
xIn
N-leiter-schutz / Ein-/Ausschaltbar:
Yes
Number Of Poles:
3
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Factor:
s
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Factor of grading:
Settingtable
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Grading:
0.05-0.8;0.01
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (on) / Factor:
s
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (on) / Factor of grading:
Settingtable
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (on) / Grading:
0.05-0.8;0.01
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Factor:
xIn
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Factor of grading:
Unit
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Grading:
0.2-1;0
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / Factor:
xIn
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / Factor of grading:
Unit
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / Grading:
0.2-1;0
Setting range / Short-circuit function, instantaneous I / Setting current Ii / Factor:
xIn
Setting range / Short-circuit function, instantaneous I / Setting current Ii / Grading:
1.5-10;0
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Grading:
0.05-0.5;0.01
Setting range / ground fault function G / lg function selectable:
Yes
Standard:
UL
Sub Brand:
3VA
Trip Type:
ETU860 LSIG LCD
Type:
3VA6
Voltage Rating:
480 V
Width:
5.41
i-trip unit / can be switched ON/OFF:
No
version / Overcurrent release / Adjustability / Short-circuit function, instantaneous I:
Yes

Recently Viewed

  • placeholder image

    3VA6340-6KQ31-0AA0

    SIEMENS INDUSTRY, INC.
    SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA63 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 400A 3-POLE (22KA...
    See more details
  • placeholder image

    137865-SKT-SHRT-05-FD0626

    HUBBARDTON FORGE
    Unfortunately, we do not have a description available for 137865-SKT-SHRT-05-FD0626. Please call (...
    See more details
  • placeholder image

    3VA6210-6JQ32-2AA0

    SIEMENS INDUSTRY, INC.
    Unfortunately, we do not have a description available for 3VA6210-6JQ32-2AA0. Please call (800) 46...
    See more details
  • placeholder image

    363008-SKT-MULT-78

    HUBBARDTON FORGE
    Unfortunately, we do not have a description available for 363008-SKT-MULT-78. Please call (800) 46...
    See more details
  • placeholder image

    3VA6440-6KQ32-0AA0

    SIEMENS INDUSTRY, INC.
    SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA64 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 400A 3-POLE (22KA...
    See more details

ADDED TO CART