Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more
information.
$8,467.36 / EA
manufacturer discounts
learn about discounts
- $7,591.43 for $1,500.00+
- $7,299.45 for $2,500.00+
- $7,007.47 for $3,500.00+
Local stock: 0
Lead time:
over 7 working days
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA63 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 400A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU856 TRIP UNIT LCD LSI GROUNG ALARM WITH METERING. SPECIAL FEATURES WITHOUT LUGS. DIMENSIONS (W x H x D) IN 7.2 x 9.8 x 5.4.
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA63 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 400A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU856 TRIP UNIT LCD LSI GROUNG ALARM WITH METERING. SPECIAL FEATURES WITHOUT LUGS. DIMENSIONS (W x H x D) IN 7.2 x 9.8 x 5.4.
150
- UPC
- 804766315114
- UNSPSC
- 39121601
- Country of Origin
- CZ
- Number Of Poles:
- 4
- Type:
- 3VA6
- Voltage Rating:
- 480 V
- Adjustable pick-up value current / of instantaneous short-circuit trip unit / Full-scale value:
- 4000
- Adjustable pick-up value current / of the current-dependent overload release / Full-scale value:
- 400
- Adjustable pick-up value current / of the current-dependent overload release / initial value:
- 160
- Connection:
- punched copper bar without any lug
- Continuous current / rated value:
- 400
- Continuous current / rated value / maximum:
- 400.0A
- Current Rating:
- 400A
- Frame:
- 400A
- Ground fault monitoring version:
- Without
- Height:
- 248
- Insulation voltage / rated value:
- 600
- Interrupt Rating:
- WITH 65kA INTERRUPTION RATING
- Length:
- 7.24
- Maximum short-circuit current breaking capacity (Icu) / at 240 V / rated value:
- 110
- Maximum short-circuit current breaking capacity (Icu) / at 415 V / rated value:
- 85
- Number Of Poles:
- 4
- Operating current / at 40 °C / rated value:
- 400
- Operating current / at 45 °C / rated value:
- 400
- Operating current / at 50 °C / rated value:
- 400
- Operating current / at 65 °C / rated value:
- 325
- Operating current / at 70 °C / rated value:
- 300
- Operating voltage / at AC / at 50/60 Hz / rated value:
- 600
- Operational short-circuit current breaking capacity (Ics) / at 240 V / rated value:
- 110kA
- Operational short-circuit current breaking capacity (Ics) / at 415 V / rated value:
- 85kA
- Operational short-circuit current breaking capacity (Ics) / at 690 V / rated value:
- 5
- Overcurrent release / Protective functions:
- LSIN
- Power loss [W] / for rated value of the current / at AC / in hot operating state / per pole:
- 23.33
- Product feature / for neutral conductors / upgradeable/retrofittable / Short-circuit and overload proof:
- No
- Product function / Intrinsic device protection:
- Yes
- Standard:
- UL
- Sub Brand:
- 3VA
- Switching capacity class of the circuit breaker:
- H
- Trip Type:
- ETU856 LSI(G) LCD
- Type:
- 3VA6
- Voltage Rating:
- 480 V
- Width:
- 184