SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA63 FRAME WITH EXTREMELY HIGH (CLASS L) BREAKING CAPACITY. 400A 4-POLE (50KAIC AT 600V) (150KAIC AT 480V). ETU330 TRIP UNIT LIG. SPECIAL FEATURES WITHOUT LUGS. DIMENSIONS (W x H x D) IN 7.2 x 9.8 x 5.4.
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA63 FRAME WITH EXTREMELY HIGH (CLASS L) BREAKING CAPACITY. 400A 4-POLE (50KAIC AT 600V) (150KAIC AT 480V). ETU330 TRIP UNIT LIG. SPECIAL FEATURES WITHOUT LUGS. DIMENSIONS (W x H x D) IN 7.2 x 9.8 x 5.4.
150
- UPC
- 804766312816
- UNSPSC
- 39121601
- Country of Origin
- CZ
- Number Of Poles:
- 4
- Type:
- 3VA6
- Voltage Rating:
- 480 V
- Ambient temperature / during operation / maximum:
- 70
- Ambient temperature / during operation / minimum:
- -25
- Ambient temperature / during storage / maximum:
- 80
- Connection:
- punched copper bar without any lug
- Current Rating:
- 400A
- Electrical endurance (switching cycles) / at AC-1 / at 380/415 V / at 50/60 Hz:
- 6000
- Electrical endurance (switching cycles) / at AC-1 / at 690 V / at 50/60 Hz:
- 4000
- Frame:
- 400A
- Height:
- 248
- Interrupt Rating:
- WITH 150kA INTERRUPTION RATING
- Length:
- 7.24
- Mechanical service life (switching cycles) / typical:
- 15000
- Number Of Poles:
- 4
- Protection class IP:
- IP40
- Reference code / acc. to DIN EN 81346-2:
- Q
- Setting range / Earth fault function G / Ig-function can be switched on/off:
- No
- Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Factor:
- s
- Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Factor of grading:
- Unit
- Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Grading:
- 0.5;0.75;1;2;3;5;8;10;14;17
- Setting range / Overload function L / I**4tI**2t can be changed over:
- No
- Setting range / Overload function L / Setting current IR / Factor:
- xIn
- Setting range / Overload function L / Setting current IR / Factor of grading:
- Unit
- Setting range / Overload function L / Setting current IR / Grading:
- 0.375;0.5;0.6;0.7;0.75;0.8;0.85;0.9;0.95;1
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / Factor of grading:
- Unit
- Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / can be switched on/off:
- No
- Short-circuit current making capacity (Icm) / at 240 V / rated value:
- 440kA
- Short-circuit current making capacity (Icm) / at 415 V / rated value:
- 330kA
- Standard:
- UL
- Sub Brand:
- 3VA
- Trip Type:
- ETU330 LIG ADJUSTMENT KNOB
- Trip class / of the L-trip / with I2t characteristic / Full-scale value:
- 17
- Trip class / of the L-trip / with I2t characteristic / initial value:
- 0.5
- Type:
- 3VA6
- Voltage Rating:
- 480 V
- Width:
- 184
- version / Overcurrent release / Adjustability / Overload function L:
- Yes