Call Us Today: (800) 462-7733
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA64 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 400A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU856 TRIP UNIT LCD LSI GROUNG ALARM WITH METERING. SPECIAL FEATURES WITHOUT LUGS. DIMENSIONS (W x H x D) IN 7.2 x 9.8 x 5.4.

Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more information.

3VA6440-6KT41-0AA0

$10,827.32 / EA

manufacturer discounts
learn about discounts

  • $9,707.26 for $1,500.00+
  • $9,333.90 for $2,500.00+
  • $8,960.54 for $3,500.00+
Available to order

Local stock: 0
Lead time: over 7 working days

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA64 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 400A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU856 TRIP UNIT LCD LSI GROUNG ALARM WITH METERING. SPECIAL FEATURES WITHOUT LUGS. DIMENSIONS (W x H x D) IN 7.2 x 9.8 x 5.4.

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA64 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 400A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU856 TRIP UNIT LCD LSI GROUNG ALARM WITH METERING. SPECIAL FEATURES WITHOUT LUGS. DIMENSIONS (W x H x D) IN 7.2 x 9.8 x 5.4.

150

UPC
804766317897
UNSPSC
39121601
Country of Origin
CZ
Number Of Poles:
4
Type:
3VA6
Voltage Rating:
480 V
Ambient temperature / during storage / minimum:
-40
Connection:
punched copper bar without any lug
Current Rating:
400A
Diken-export / tripping characteristics / Upper tolerance band:
AK_3VA6_4_400A_ETU5u8_MuHuCuL_oT
Frame:
600A
Height:
248
Interrupt Rating:
WITH 65kA INTERRUPTION RATING
Length:
7.24
Maximum short-circuit current breaking capacity (Icu) / at 690 V / rated value:
6
N-Leiterschutz N / Einstellparameter Strom InN / Einheit der Werteliste:
Unit
N-Leiterschutz N / Einstellparameter Strom InN / Werteliste:
0.2-1.5;0
Number Of Poles:
4
Operating current / at 55 °C / rated value:
400
Operating current / at 60 °C / rated value:
400
Product function / Ground fault protection:
No
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / max:
1
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / max:
1
Setting range / Overload function L / Delay time tR / I**2t characteristic curve / max:
25
Setting range / Overload function L / Setting current IR / max:
1
Setting range / Short-circuit function, instantaneous I / Setting current Ii / max:
12
Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / max:
10
Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / max:
10
Setting range / Short-circuit function, short-time delay / can be switched on/off:
No
Standard:
UL
Sub Brand:
3VA
Trip Type:
ETU856 LSI(G) LCD
Tripping characteristics / Lower tolerance band:
AK_3VA6_4_400A_ETU5u8_MuHuCuL_uT
Type:
3VA6
Voltage Rating:
480 V
Width:
184

Recently Viewed

  • placeholder image

    3VA6440-6KT41-0AA0

    SIEMENS INDUSTRY, INC.
    SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA64 FRAME WITH HIGH (CLASS H) BREAKING CAPACITY. 400A 4-POLE (22KA...
    See more details
  • placeholder image

    3VA6140-5KP31-0AA0

    SIEMENS INDUSTRY, INC.
    SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA61 FRAME WITH MEDIUM (CLASS M) BREAKING CAPACITY. 40A 3-POLE (18K...
    See more details
  • placeholder image

    DC-WE05-S927S-BZ

    W.A.C. LIGHTING COMPANY
    Unfortunately, we do not have a description available for DC-WE05-S927S-BZ. Please call (800) 462-...
    See more details
  • placeholder image

    203050-SKT-02

    HUBBARDTON FORGE
    Unfortunately, we do not have a description available for 203050-SKT-02. Please call (800) 462-773...
    See more details
  • placeholder image

    3VA4170-4ED24-1AA0

    SIEMENS INDUSTRY, INC.
    SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH THERMAL - MAGNETIC TRIP UNIT. 3VA41 FRAME WITH STANDARD (CLASS S) BREAKING CAPACITY. 70A 2...
    See more details

ADDED TO CART