Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more
information.
$6,526.57 / EA
manufacturer discounts
learn about discounts
- $5,851.40 for $1,500.00+
- $5,626.35 for $2,500.00+
- $5,401.30 for $3,500.00+
Local stock: 0
Lead time:
over 7 working days
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM LOW (CLASS M) BREAKING CAPACITY. 600A 4-POLE (18KAIC AT 600V) (35KAIC AT 480V). ETU320 TRIP UNIT LI. SPECIAL FEATURES CONNECTION WITHLUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D) IN 11.1 x 12.5 x 5.8.
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM LOW (CLASS M) BREAKING CAPACITY. 600A 4-POLE (18KAIC AT 600V) (35KAIC AT 480V). ETU320 TRIP UNIT LI. SPECIAL FEATURES CONNECTION WITHLUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D) IN 11.1 x 12.5 x 5.8.
150
- UPC
- 804766978753
- Number Of Poles:
- 4
- Ambient temperature / during storage / minimum:
- -40
- Breaking capacity current / at AC / at 240 V / acc. to UL 489 / rated value:
- 100
- Breaking capacity current / at AC / at 480 V / acc. to UL 489 / rated value:
- 35
- Breaking capacity current / at AC / at 600 V / acc. to UL 489 / rated value:
- 25
- Depth [in]:
- 4.7
- Design of the load switch / acc. to UL 489 / Heating, Air Conditioning, and Refrigeration circuit breaker (HACR Type):
- Yes
- Electrical endurance (switching cycles) / at 480 V / at 50/60 Hz:
- 5100
- Electrical endurance (switching cycles) / at 600 V / at 50/60 Hz:
- 3500
- Height:
- 328
- Height [in]:
- 12.6
- Maximum short-circuit current breaking capacity (Icu) / at 690 V / rated value:
- 25
- N-Leiter Schutz / einstellbar:
- Yes
- N-Leiterschutz N / Einstellparameter Strom InN / Einheit der Werteliste:
- Unit
- N-Leiterschutz N / Einstellparameter Strom InN / Format der Werteliste:
- xIn
- N-Leiterschutz N / Einstellparameter Strom InN / Werteliste:
- 0.5;1
- N-leiter-schutz / Ein-/Ausschaltbar:
- Yes
- Number Of Poles:
- 4
- Product function / Ground fault protection:
- No
- Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Factor:
- s
- Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Factor of grading:
- Unit
- Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Grading:
- 0.5;0.75;1;2;3;5;8;10;14;17
- Setting range / Overload function L / Delay time tR / I**2t characteristic curve / max:
- 17
- Setting range / Overload function L / Setting current IR / Factor of grading:
- Unit
- Setting range / Overload function L / Setting current IR / Grading:
- 0.417;0.5;0.583;0.667;0.75;0.833;0.875;0.917;0.958;1
- Setting range / Overload function L / Setting current IR / max:
- 1
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / Factor:
- xIn
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / Factor of grading:
- Unit
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / Grading:
- 1.5;2;2.5;3;4;5;6;8;10;12
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / max:
- 12
- Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / can be switched on/off:
- No
- Setting range / ground fault function G / lg function selectable:
- No
- Trip class / of the L-trip / with I2t characteristic / Full-scale value:
- 17
- Trip class / of the L-trip / with I2t characteristic / initial value:
- 0.5
- Width:
- 280
- Width [in]:
- 11
- i-trip unit / can be switched ON/OFF:
- No
- version / Overcurrent release / Adjustability / Short-circuit function, instantaneous I:
- Yes