Call Us Today: (800) 462-7733
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM LOW (CLASS M) BREAKING CAPACITY. 600A 4-POLE (18KAIC AT 600V) (35KAIC AT 480V). ETU350 TRIP UNIT LSI. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER. 100 PERCENT RATED. DIMENSIONS (W x H x D) IN 11.1 x12.5 x 5.8.

Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more information.

3VA6560-5HN42-2AA0

$8,966.92 / EA

manufacturer discounts
learn about discounts

  • $8,039.30 for $1,500.00+
  • $7,730.10 for $2,500.00+
  • $7,420.90 for $3,500.00+
Available to order

Local stock: 0
Lead time: over 7 working days

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM LOW (CLASS M) BREAKING CAPACITY. 600A 4-POLE (18KAIC AT 600V) (35KAIC AT 480V). ETU350 TRIP UNIT LSI. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER. 100 PERCENT RATED. DIMENSIONS (W x H x D) IN 11.1 x12.5 x 5.8.

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM LOW (CLASS M) BREAKING CAPACITY. 600A 4-POLE (18KAIC AT 600V) (35KAIC AT 480V). ETU350 TRIP UNIT LSI. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER. 100 PERCENT RATED. DIMENSIONS (W x H x D) IN 11.1 x12.5 x 5.8.

150

UPC
804766978845
Number Of Poles:
4
Electrical endurance (switching cycles) / at AC-1 / at 380/415 V / at 50/60 Hz:
5100
Electrical endurance (switching cycles) / at AC-1 / at 690 V / at 50/60 Hz:
3500
Height:
328
Mechanical service life (switching cycles) / typical:
10000
Number Of Poles:
4
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Factor:
s
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Factor of grading:
Unit
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Grading:
0.1;0.3
Setting range / Earth fault function G / Ig-function can be switched on/off:
Yes
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Factor:
xIn
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Factor of grading:
Unit
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Grading:
0.2;0.4;0.6;0.8;1
Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Factor:
s
Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Factor of grading:
Unit
Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Grading:
0.5;0.75;1;2;3;5;8;10;14;17
Setting range / Overload function L / I**4tI**2t can be changed over:
No
Setting range / Overload function L / Setting current IR / Factor:
xIn
Setting range / Overload function L / Setting current IR / Factor of grading:
Unit
Setting range / Overload function L / Setting current IR / Grading:
0.417;0.5;0.583;0.667;0.75;0.833;0.875;0.917;0.958;1
Setting range / Short-circuit function, instantaneous I / Setting current Ii / Factor:
xIn
Setting range / Short-circuit function, instantaneous I / Setting current Ii / Factor of grading:
Fixed
Setting range / Short-circuit function, instantaneous I / Setting current Ii / Grading:
12
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Factor:
s
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Factor of grading:
Unit
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Grading:
0.04;0.08;0.15;0.22;0.3;0.4
Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / Factor:
xIr
Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / Factor of grading:
Unit
Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / can be switched on/off:
No
Setting range / ground fault function G / lg function selectable:
No
Short-circuit current making capacity (Icm) / at 240 V / rated value:
187kA
Short-circuit current making capacity (Icm) / at 415 V / rated value:
121kA
Trip class / of the L-trip / with I2t characteristic / Full-scale value:
17
Trip class / of the L-trip / with I2t characteristic / initial value:
0.5
Width:
280
i-trip unit / can be switched ON/OFF:
No
version / Overcurrent release / Adjustability / Overload function L:
Yes
version / Overcurrent release / Adjustability / Short-circuit function, instantaneous I:
No

Recently Viewed

  • placeholder image

    3VA6560-5HN42-2AA0

    SIEMENS INDUSTRY, INC.
    SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM LOW (CLASS M) BREAKING CAPACITY. 600A 4-POLE...
    See more details
  • placeholder image

    3VA1120-5EF32-0AA0

    SIEMENS INDUSTRY, INC.
    SIEMENS LOW VOLTAGE 3VA IEC MOLDED CASE CIRCUIT BREAKER WITH THERMAL - MAGNETICTRIP UNIT. 3VA11 FRAME WITH MEDIUM (CLASS M) BREAKING CAPACITY. 20A 3-P...
    See more details
  • placeholder image

    3VA6225-8HN36-0AA0

    SIEMENS INDUSTRY, INC.
    Unfortunately, we do not have a description available for 3VA6225-8HN36-0AA0. Please call (800) 46...
    See more details
  • placeholder image

    GM2605-L30-30K-B

    DABMAR LIGHTING INC.
    Unfortunately, we do not have a description available for GM2605-L30-30K-B. Please call (800) 462-...
    See more details
  • placeholder image

    GM6603-L189-50K-VG

    DABMAR LIGHTING INC.
    Unfortunately, we do not have a description available for GM6603-L189-50K-VG. Please call (800) 46...
    See more details

ADDED TO CART