SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM LOW (CLASS M) BREAKING CAPACITY. 600A 4-POLE (18KAIC AT 600V) (35KAIC AT 480V). ETU350 TRIP UNIT LSI. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER. 100 PERCENT RATED. DIMENSIONS (W x H x D) IN 11.1 x12.5 x 5.8.
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM LOW (CLASS M) BREAKING CAPACITY. 600A 4-POLE (18KAIC AT 600V) (35KAIC AT 480V). ETU350 TRIP UNIT LSI. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER. 100 PERCENT RATED. DIMENSIONS (W x H x D) IN 11.1 x12.5 x 5.8.
150
- UPC
- 804766978845
- Number Of Poles:
- 4
- Electrical endurance (switching cycles) / at AC-1 / at 380/415 V / at 50/60 Hz:
- 5100
- Electrical endurance (switching cycles) / at AC-1 / at 690 V / at 50/60 Hz:
- 3500
- Height:
- 328
- Mechanical service life (switching cycles) / typical:
- 10000
- Number Of Poles:
- 4
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Factor:
- s
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Factor of grading:
- Unit
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Grading:
- 0.1;0.3
- Setting range / Earth fault function G / Ig-function can be switched on/off:
- Yes
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Factor:
- xIn
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Factor of grading:
- Unit
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Grading:
- 0.2;0.4;0.6;0.8;1
- Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Factor:
- s
- Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Factor of grading:
- Unit
- Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Grading:
- 0.5;0.75;1;2;3;5;8;10;14;17
- Setting range / Overload function L / I**4tI**2t can be changed over:
- No
- Setting range / Overload function L / Setting current IR / Factor:
- xIn
- Setting range / Overload function L / Setting current IR / Factor of grading:
- Unit
- Setting range / Overload function L / Setting current IR / Grading:
- 0.417;0.5;0.583;0.667;0.75;0.833;0.875;0.917;0.958;1
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / Factor:
- xIn
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / Factor of grading:
- Fixed
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / Grading:
- 12
- Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Factor:
- s
- Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Factor of grading:
- Unit
- Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Grading:
- 0.04;0.08;0.15;0.22;0.3;0.4
- Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / Factor:
- xIr
- Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / Factor of grading:
- Unit
- Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / can be switched on/off:
- No
- Setting range / ground fault function G / lg function selectable:
- No
- Short-circuit current making capacity (Icm) / at 240 V / rated value:
- 187kA
- Short-circuit current making capacity (Icm) / at 415 V / rated value:
- 121kA
- Trip class / of the L-trip / with I2t characteristic / Full-scale value:
- 17
- Trip class / of the L-trip / with I2t characteristic / initial value:
- 0.5
- Width:
- 280
- i-trip unit / can be switched ON/OFF:
- No
- version / Overcurrent release / Adjustability / Overload function L:
- Yes
- version / Overcurrent release / Adjustability / Short-circuit function, instantaneous I:
- No