SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM LOW (CLASS M) BREAKING CAPACITY. 600A 4-POLE (18KAIC AT 600V) (35KAIC AT 480V). ETU860 TRIP UNIT LCD LSIG WITH METERING. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D) IN 11.1 x 12.5 x 5.8.

Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more information.

3VA6560-5KQ42-0AA0

$9,300.47 / EA

manufacturer discounts
learn about discounts

  • $8,338.36 for $1,500.00+
  • $8,017.65 for $2,500.00+
  • $7,696.94 for $3,500.00+
Available to order

Local stock: 0
Lead time: over 7 working days

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM LOW (CLASS M) BREAKING CAPACITY. 600A 4-POLE (18KAIC AT 600V) (35KAIC AT 480V). ETU860 TRIP UNIT LCD LSIG WITH METERING. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D) IN 11.1 x 12.5 x 5.8.

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM LOW (CLASS M) BREAKING CAPACITY. 600A 4-POLE (18KAIC AT 600V) (35KAIC AT 480V). ETU860 TRIP UNIT LCD LSIG WITH METERING. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D) IN 11.1 x 12.5 x 5.8.

150

UPC
804766978982
Number Of Poles:
4
Ambient temperature / during operation / maximum:
70
Ambient temperature / during operation / minimum:
-25
Ambient temperature / during storage / maximum:
80
Electrical endurance (switching cycles) / at AC-1 / at 380/415 V / at 50/60 Hz:
5100
Electrical endurance (switching cycles) / at AC-1 / at 690 V / at 50/60 Hz:
3500
Height:
328
Mechanical service life (switching cycles) / typical:
10000
Number Of Poles:
4
Reference code / acc. to DIN EN 81346-2:
Q
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Factor:
s
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Grading:
0.05-0.8;0.01
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / Factor:
xIn
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / Factor of grading:
Unit
Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Factor:
s
Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Factor of grading:
Settingtable
Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Grading:
0.5-25;0.1
Setting range / Overload function L / I**4tI**2t can be changed over:
No
Setting range / Overload function L / Setting current IR / Factor:
xIn
Setting range / Overload function L / Setting current IR / Factor of grading:
Unit
Setting range / Overload function L / Setting current IR / Grading:
0.4-1;0
Setting range / Short-circuit function, instantaneous I / Setting current Ii / Grading:
1.5-12;0
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (off) / Factor of grading:
Settingtable
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Factor of grading:
Settingtable
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Grading:
0.05-0.5;0.01
Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / Factor:
xIn
Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / Factor:
xIn
Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / Factor of grading:
Unit
Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / can be switched on/off:
Yes
Setting range / ground fault function G / lg function selectable:
Yes
Short-circuit current making capacity (Icm) / at 240 V / rated value:
187kA
Short-circuit current making capacity (Icm) / at 415 V / rated value:
121kA
Trip class / of the L-trip / with I2t characteristic / Full-scale value:
25
Trip class / of the L-trip / with I2t characteristic / initial value:
0.5
Width:
280
i-trip unit / can be switched ON/OFF:
No
version / Overcurrent release / Adjustability / Overload function L:
Yes
version / Overcurrent release / Adjustability / Short-circuit function, instantaneous I:
Yes

Recently Viewed

  • placeholder image

    3VA6560-5KQ42-0AA0

    SIEMENS INDUSTRY, INC.
    SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM LOW (CLASS M) BREAKING CAPACITY. 600A 4-POLE...
    See more details
  • placeholder image

    D5100-L6-30K-10T-G

    DABMAR LIGHTING INC.
    Unfortunately, we do not have a description available for D5100-L6-30K-10T-G. Please call (800) 46...
    See more details
  • placeholder image

    131040-LED-LONG-10-27-LC-HF-GG0670

    HUBBARDTON FORGE
    Unfortunately, we do not have a description available for 131040-LED-LONG-10-27-LC-HF-GG0670. Please call See more details
  • placeholder image

    GM1823-L27-27K-B

    DABMAR LIGHTING INC.
    Unfortunately, we do not have a description available for GM1823-L27-27K-B. Please call (800) 462-...
    See more details
  • placeholder image

    F-L22/30/50K/D/BL-87

    TOPAZ LIGHTING CORP.
    Unfortunately, we do not have a description available for F-L22/30/50K/D/BL-87. Please call (800)...
    See more details

ADDED TO CART