Call Us Today: (800) 462-7733
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM HIGH (CLASS C) BREAKING CAPACITY. 600A 4-POLE (35KAICAT 600V) (100KAIC AT 480V). ETU560 TRIP UNIT LCD LSIG. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D) IN 11.1 x 12.5 x 5.8.

Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more information.

3VA6560-7JQ42-0AA0

$17,590.36 / EA

manufacturer discounts
learn about discounts

  • $15,770.66 for $1,500.00+
  • $15,164.10 for $2,500.00+
  • $14,557.54 for $3,500.00+
Available to order

Local stock: 0
Lead time: over 7 working days

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM HIGH (CLASS C) BREAKING CAPACITY. 600A 4-POLE (35KAICAT 600V) (100KAIC AT 480V). ETU560 TRIP UNIT LCD LSIG. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D) IN 11.1 x 12.5 x 5.8.

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM HIGH (CLASS C) BREAKING CAPACITY. 600A 4-POLE (35KAICAT 600V) (100KAIC AT 480V). ETU560 TRIP UNIT LCD LSIG. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D) IN 11.1 x 12.5 x 5.8.

150

UPC
804766979408
Number Of Poles:
4
Height:
328
Number Of Poles:
4
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Factor:
s
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Factor of grading:
Settingtable
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Grading:
0.05-0.8;0.01
Setting range / Earth fault function G / Ig-function can be switched on/off:
Yes
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Factor:
xIn
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Factor of grading:
Unit
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / Factor:
xIn
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / Factor of grading:
Unit
Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Factor:
s
Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Factor of grading:
Settingtable
Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Grading:
0.5-25;0.1
Setting range / Overload function L / Setting current IR / Factor:
xIn
Setting range / Overload function L / Setting current IR / Factor of grading:
Unit
Setting range / Overload function L / Setting current IR / Grading:
0.4-1;0
Setting range / Short-circuit function, instantaneous I / Setting current Ii / Factor:
xIn
Setting range / Short-circuit function, instantaneous I / Setting current Ii / Factor of grading:
Unit
Setting range / Short-circuit function, instantaneous I / Setting current Ii / Grading:
1.5-12;0
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (off) / Factor:
s
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (off) / Factor of grading:
Settingtable
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (off) / Grading:
0.05-0.5;0.01
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Factor:
s
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Factor of grading:
Settingtable
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Grading:
0.05-0.5;0.01
Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / Factor:
xIn
Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / Factor of grading:
Unit
Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / Factor:
xIn
Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / Factor of grading:
Unit
Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / can be switched on/off:
Yes
Setting range / ground fault function G / lg function selectable:
Yes
Trip class / of the L-trip / with I2t characteristic / Full-scale value:
25
Trip class / of the L-trip / with I2t characteristic / initial value:
0.5
Width:
280
i-trip unit / can be switched ON/OFF:
No
version / Overcurrent release / Adjustability / Overload function L:
Yes
version / Overcurrent release / Adjustability / Short-circuit function, instantaneous I:
Yes

Recently Viewed

  • placeholder image

    3VA6560-7JQ42-0AA0

    SIEMENS INDUSTRY, INC.
    SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM HIGH (CLASS C) BREAKING CAPACITY. 600A 4-POL...
    See more details
  • placeholder image

    137525-SKT-SHRT-05-GG0182

    HUBBARDTON FORGE
    Unfortunately, we do not have a description available for 137525-SKT-SHRT-05-GG0182. Please call (...
    See more details
  • placeholder image

    131203-SKT-STND-89-FD0710

    HUBBARDTON FORGE
    Unfortunately, we do not have a description available for 131203-SKT-STND-89-FD0710. Please call (...
    See more details
  • placeholder image

    NMIOTL-12-NF-FF-30X-10-MPW

    NORA LIGHTING
    Unfortunately, we do not have a description available for NMIOTL-12-NF-FF-30X-10-MPW. Please call ...
    See more details
  • placeholder image

    MSD-483-LB-D-50L-3090-BK

    JESCO LIGHTING GROUP
    Unfortunately, we do not have a description available for MSD-483-LB-D-50L-3090-BK. Please call (8...
    See more details

ADDED TO CART