SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM HIGH (CLASS C) BREAKING CAPACITY. 600A 4-POLE (35KAICAT 600V) (100KAIC AT 480V). ETU860 TRIP UNIT LCD LSIG WITH METERING. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D) IN 11.1 x 12.5 x 5.8.
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM HIGH (CLASS C) BREAKING CAPACITY. 600A 4-POLE (35KAICAT 600V) (100KAIC AT 480V). ETU860 TRIP UNIT LCD LSIG WITH METERING. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D) IN 11.1 x 12.5 x 5.8.
150
- UPC
- 804766979484
- Number Of Poles:
- 4
- Ambient temperature / during storage / minimum:
- -40
- Breaking capacity current / at AC / at 240 V / acc. to UL 489 / rated value:
- 200
- Depth [in]:
- 4.7
- Height:
- 328
- Height [in]:
- 12.6
- Maximum short-circuit current breaking capacity (Icu) / at 690 V / rated value:
- 35
- N-Leiter Schutz / einstellbar:
- Yes
- N-Leiterschutz N / Einstellparameter Strom InN / Einheit der Werteliste:
- Unit
- N-Leiterschutz N / Einstellparameter Strom InN / Format der Werteliste:
- xIn
- N-leiter-schutz / Ein-/Ausschaltbar:
- Yes
- Number Of Poles:
- 4
- Product function / Ground fault protection:
- Yes
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Factor:
- s
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Factor of grading:
- Settingtable
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Grading:
- 0.05-0.8;0.01
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (on) / Factor:
- s
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (on) / Factor of grading:
- Settingtable
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (on) / Grading:
- 0.05-0.8;0.01
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Factor:
- xIn
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Factor of grading:
- Unit
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Grading:
- 0.2-1;0
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / max:
- 1
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / Factor:
- xIn
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / Factor of grading:
- Unit
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / Grading:
- 0.2-1;0
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / max:
- 1
- Setting range / Overload function L / Delay time tR / I**2t characteristic curve / max:
- 25
- Setting range / Overload function L / Setting current IR / max:
- 1
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / max:
- 12
- Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Grading:
- 0.05-0.5;0.01
- Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / max:
- 12
- Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / max:
- 12
- Setting range / Short-circuit function, short-time delay / can be switched on/off:
- No
- Setting range / ground fault function G / lg function selectable:
- Yes
- Width:
- 280
- Width [in]:
- 11
- i-trip unit / can be switched ON/OFF:
- No