Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more
information.
$9,890.86 / EA
manufacturer discounts
learn about discounts
- $8,867.66 for $1,500.00+
- $8,526.60 for $2,500.00+
- $8,185.54 for $3,500.00+
Local stock: 0
Lead time:
over 7 working days
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM LOW (CLASS M) BREAKING CAPACITY. 800A 4-POLE (18KAIC AT 600V) (35KAIC AT 480V). ETU550 TRIP UNIT LCD LSI. SPECIAL FEATURES CONNECTIONWITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D) IN 11.1 x 12.5 x 5.8.
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM LOW (CLASS M) BREAKING CAPACITY. 800A 4-POLE (18KAIC AT 600V) (35KAIC AT 480V). ETU550 TRIP UNIT LCD LSI. SPECIAL FEATURES CONNECTIONWITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D) IN 11.1 x 12.5 x 5.8.
150
- UPC
- 804766979668
- Number Of Poles:
- 4
- Adjustable delay time / of S-trip / with I2t characteristic / Full-scale value:
- 0.50s
- Adjustable delay time / of S-trip / with I2t characteristic / initial value:
- 0.05s
- Adjustable delay time / of S-trip / with standard characteristic / Full-scale value:
- 0.50s
- Adjustable delay time / of S-trip / with standard characteristic / initial value:
- 0.05s
- Adjustable pick-up value current / of instantaneous short-circuit trip unit / Full-scale value:
- 8000
- Adjustable pick-up value current / of instantaneous short-circuit trip unit / initial value:
- 1200
- Adjustable pick-up value current / of the current-dependent overload release / Full-scale value:
- 800
- Adjustable pick-up value current / of the current-dependent overload release / initial value:
- 320
- Adjustable pick-up value current / of the short-time delayed short-circuit release / Full-scale value:
- 8000.00A
- Adjustable pick-up value current / of the short-time delayed short-circuit release / initial value:
- 480.00A
- Ambient temperature / during operation / maximum:
- 70
- Ambient temperature / during operation / minimum:
- -25
- Ambient temperature / during storage / maximum:
- 80
- Electrical endurance (switching cycles) / at AC-1 / at 380/415 V / at 50/60 Hz:
- 5800
- Ground fault monitoring version:
- Without
- Height:
- 328
- Insulation voltage / rated value:
- 600
- Maximum short-circuit current breaking capacity (Icu) / at 240 V / rated value:
- 85
- Maximum short-circuit current breaking capacity (Icu) / at 415 V / rated value:
- 55
- Mounting type:
- fixedmounting
- Number Of Poles:
- 4
- Operating voltage / at AC / at 50/60 Hz / rated value:
- 600
- Operational short-circuit current breaking capacity (Ics) / at 240 V / rated value:
- 85kA
- Operational short-circuit current breaking capacity (Ics) / at 415 V / rated value:
- 55kA
- Operational short-circuit current breaking capacity (Ics) / at 690 V / rated value:
- 19
- Power loss [W] / for rated value of the current / at AC / in hot operating state / per pole:
- 77
- Product feature / for neutral conductors / upgradeable/retrofittable / Short-circuit and overload proof:
- No
- Product variations:
- Advancedapplications
- Protection class IP:
- IP40
- Protection class IP / on the front:
- IP40
- Reference code / acc. to DIN EN 81346-2:
- Q
- Setting range / Overload function L / IR can be switched on:
- No
- Switching capacity class of the circuit breaker:
- M
- Width:
- 280