SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM LOW (CLASS M) BREAKING CAPACITY. 800A 4-POLE (18KAIC AT 600V) (35KAIC AT 480V). ETU560 TRIP UNIT LCD LSIG. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER. 100 PERCENT RATED. DIMENSIONS (W x H x D) IN 11.1 x 12.5 x 5.8.
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM LOW (CLASS M) BREAKING CAPACITY. 800A 4-POLE (18KAIC AT 600V) (35KAIC AT 480V). ETU560 TRIP UNIT LCD LSIG. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER. 100 PERCENT RATED. DIMENSIONS (W x H x D) IN 11.1 x 12.5 x 5.8.
150
- UPC
- 804766981241
- Number Of Poles:
- 4
- Ambient temperature / during storage / minimum:
- -40
- Design of the product:
- Systemprotection
- Height:
- 328
- N-Leiter Schutz / einstellbar:
- Yes
- N-Leiterschutz N / Einstellparameter Strom InN / Einheit der Werteliste:
- Unit
- N-Leiterschutz N / Einstellparameter Strom InN / Format der Werteliste:
- xIn
- N-Leiterschutz N / Einstellparameter Strom InN / Werteliste:
- 0.2-1;0
- N-leiter-schutz / Ein-/Ausschaltbar:
- Yes
- Number Of Poles:
- 4
- Product designation:
- Molded-casecircuitbreaker
- Product designation / according to UL file:
- MMAE
- Product function / communication function:
- Yes
- Product function / other measurement function:
- No
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Factor:
- s
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Factor of grading:
- Settingtable
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Grading:
- 0.05-0.8;0.01
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (on) / Factor:
- s
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (on) / Factor of grading:
- Settingtable
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (on) / Grading:
- 0.05-0.8;0.01
- Setting range / Earth fault function G / Ig-function can be switched on/off:
- Yes
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Factor:
- xIn
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Factor of grading:
- Unit
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Grading:
- 0.2-1;0
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / Factor:
- xIn
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / Factor of grading:
- Unit
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / Grading:
- 0.2-1;0
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / Factor:
- xIn
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / Factor of grading:
- Unit
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / Grading:
- 1.5-10;0
- Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Grading:
- 0.05-0.5;0.01
- Setting range / ground fault function G / lg function selectable:
- Yes
- Simaris relevant:
- -
- Suitability for use:
- systemprotection
- Width:
- 280
- i-trip unit / can be switched ON/OFF:
- No
- product brand name:
- SENTRON
- version / Overcurrent release / Adjustability / Short-circuit function, instantaneous I:
- Yes