SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM LOW (CLASS M) BREAKING CAPACITY. 800A 4-POLE (18KAIC AT 600V) (35KAIC AT 480V). ETU556 TRIP UNIT LCD LSI GROUND ALARM. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D) IN 11.1 x 12.5 x 5.8.
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM LOW (CLASS M) BREAKING CAPACITY. 800A 4-POLE (18KAIC AT 600V) (35KAIC AT 480V). ETU556 TRIP UNIT LCD LSI GROUND ALARM. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D) IN 11.1 x 12.5 x 5.8.
150
- UPC
- 804766979712
- Number Of Poles:
- 4
- Adjustable delay time / for G-tripping / with I2t characteristic / Full-scale value:
- 0.80s
- Adjustable delay time / for G-tripping / with I2t characteristic / initial value:
- 0.05s
- Adjustable delay time / of S-trip / with standard characteristic / initial value:
- 0.05s
- Adjustable pick-up value current / for G-tripping / with standard characteristic / Full-scale value:
- 800.00A
- Adjustable pick-up value current / for G-tripping / with standard characteristic / initial value:
- 160.00A
- Adjustable pick-up value current / of instantaneous short-circuit trip unit / Full-scale value:
- 8000
- Adjustable pick-up value current / of instantaneous short-circuit trip unit / initial value:
- 1200
- Adjustable pick-up value current / of the current-dependent overload release / Full-scale value:
- 800
- Adjustable pick-up value current / of the short-time delayed short-circuit release / Full-scale value:
- 8000.00A
- Adjustable pick-up value current / of the short-time delayed short-circuit release / initial value:
- 480.00A
- Continuous current / rated value:
- 800
- Continuous current / rated value / maximum:
- 800.0A
- Design of the operating mechanism:
- togglehandle
- Design of the overcurrent release:
- ETU556
- Design of the product:
- Systemprotection
- Ground fault monitoring version:
- Without
- Height:
- 328
- Insulation voltage / rated value:
- 600
- Number Of Poles:
- 4
- Operating voltage / at AC / at 50/60 Hz / rated value:
- 600
- Operational short-circuit current breaking capacity (Ics) / at 240 V / rated value:
- 85kA
- Overcurrent release / Protective functions:
- LSIN
- Power loss [W] / for rated value of the current / at AC / in hot operating state / per pole:
- 77
- Product component / display:
- Yes
- Product designation:
- Molded-casecircuitbreaker
- Product designation / according to UL file:
- MMAE
- Product feature / for neutral conductors / upgradeable/retrofittable / Short-circuit and overload proof:
- No
- Product function / Intrinsic device protection:
- Yes
- Product function / communication function:
- Yes
- Product function / other measurement function:
- Yes
- Protective function of the overcurrent release:
- LSI
- Simaris relevant:
- -
- Suitability for use:
- systemprotection
- Type of the driving mechanism / motor drive:
- No
- Width:
- 280
- circuit-breaker / Design:
- 3VA6
- product brand name: