Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more
information.
$17,180.59 / EA
manufacturer discounts
learn about discounts
- $15,403.28 for $1,500.00+
- $14,810.85 for $2,500.00+
- $14,218.42 for $3,500.00+
Local stock: 0
Lead time:
over 7 working days
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM (CLASS H) BREAKING CAPACITY. 800A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU330 TRIP UNIT LIG. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER. 100 PERCENT RATED. DIMENSIONS (W x H x D) IN 11.1 x 12.5 x 5.8.
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM (CLASS H) BREAKING CAPACITY. 800A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU330 TRIP UNIT LIG. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER. 100 PERCENT RATED. DIMENSIONS (W x H x D) IN 11.1 x 12.5 x 5.8.
150
- UPC
- 804766979873
- Number Of Poles:
- 4
- Ambient temperature / during storage / minimum:
- -40
- Breaking capacity current / at AC / at 240 V / acc. to UL 489 / rated value:
- 150
- Breaking capacity current / at AC / at 480 V / acc. to UL 489 / rated value:
- 65
- Breaking capacity current / at AC / at 600 V / acc. to UL 489 / rated value:
- 35
- Certificate of suitability / as approval for NAVAL (no combat vessels) / Supplement SB:
- Yes
- Depth [in]:
- 4.7
- Design of the load switch / acc. to UL 489 / Heating, Air Conditioning, and Refrigeration circuit breaker (HACR Type):
- Yes
- Electrical endurance (switching cycles) / at 480 V / at 50/60 Hz:
- 5800
- Electrical endurance (switching cycles) / at 600 V / at 50/60 Hz:
- 4000
- Height:
- 328
- Height [in]:
- 12.6
- Marking / of circuit breaker / acc. to UL 489 / 100%-rated breaker:
- Yes
- Maximum short-circuit current breaking capacity (Icu) / at 690 V / rated value:
- 35
- N-Leiter Schutz / einstellbar:
- Yes
- N-Leiterschutz N / Einstellparameter Strom InN / Einheit der Werteliste:
- Unit
- N-Leiterschutz N / Einstellparameter Strom InN / Format der Werteliste:
- xIn
- N-Leiterschutz N / Einstellparameter Strom InN / Werteliste:
- 0.5;1
- N-leiter-schutz / Ein-/Ausschaltbar:
- Yes
- Number Of Poles:
- 4
- Product function / Ground fault protection:
- Yes
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Factor:
- s
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Factor of grading:
- Unit
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Grading:
- 0.1;0.3
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Factor:
- xIn
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Factor of grading:
- Unit
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Grading:
- 0.2;0.4;0.6;0.8;1
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / max:
- 1
- Setting range / Overload function L / Delay time tR / I**2t characteristic curve / max:
- 17
- Setting range / Overload function L / Setting current IR / max:
- 1
- Setting range / Overload function L / Setting current IR / min:
- 0.394
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / Grading:
- 1.5;2;2.5;3;4;5;6;8;9;10
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / max:
- 10
- Setting range / ground fault function G / lg function selectable:
- No
- Width:
- 280
- Width [in]:
- 11
- i-trip unit / can be switched ON/OFF:
- No
- version / Overcurrent release / Adjustability / Short-circuit function, instantaneous I:
- Yes