Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more
information.
Videos & documents
Documents
3VA6580-6JP42-0AA0
SKU: 3VA6580-6JP42-0AA0
MPN: 3VA6580-6JP42-0AA0
Key specs
View all- Number Of Poles
- 4
Description
Product overview
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM (CLASS H) BREAKING CAPACITY. 800A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU550 TRIP UNIT LCD LSI. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D) IN 11.1 x 12.5 x 5.8.
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM (CLASS H) BREAKING CAPACITY. 800A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU550 TRIP UNIT LCD LSI. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D) IN 11.1 x 12.5 x 5.8.
Manufacturer highlights
Additional manufacturer notes
- Short name
- S-A
- Feed description
- S-A 3VA6580-6JP42-0AA0 BRKR 3VA65 4
- Invoice description
- BRKR 3VA65 4P 800A 65KA ETU5-LSI NUT
Specifications
- UPC
- 804766979941
- Number Of Poles
- 4
- Adjustable delay time / of S-trip / with I2t characteristic / Full-scale value
- 0.50s
- Adjustable delay time / of S-trip / with I2t characteristic / initial value
- 0.05s
- Adjustable delay time / of S-trip / with standard characteristic / Full-scale value
- 0.50s
- Adjustable delay time / of S-trip / with standard characteristic / initial value
- 0.05s
- Adjustable pick-up value current / of instantaneous short-circuit trip unit / Full-scale value
- 8000
- Adjustable pick-up value current / of instantaneous short-circuit trip unit / initial value
- 1200
- Adjustable pick-up value current / of the current-dependent overload release / Full-scale value
- 800
- Adjustable pick-up value current / of the current-dependent overload release / initial value
- 320
- Adjustable pick-up value current / of the short-time delayed short-circuit release / Full-scale value
- 8000.00A
- Adjustable pick-up value current / of the short-time delayed short-circuit release / initial value
- 480.00A
- Ambient temperature / during operation / maximum
- 70
- Ambient temperature / during operation / minimum
- -25
- Ambient temperature / during storage / maximum
- 80
- Electrical endurance (switching cycles) / at AC-1 / at 380/415 V / at 50/60 Hz
- 5800
- Electrical endurance (switching cycles) / at AC-1 / at 690 V / at 50/60 Hz
- 4000
- Height
- 328
- Maximum short-circuit current breaking capacity (Icu) / at 240 V / rated value
- 110
- Maximum short-circuit current breaking capacity (Icu) / at 415 V / rated value
- 85
- Mechanical service life (switching cycles) / typical
- 10000
- Mounting type
- fixedmounting
- Number Of Poles
- 4
- Operational short-circuit current breaking capacity (Ics) / at 240 V / rated value
- 110kA
- Operational short-circuit current breaking capacity (Ics) / at 415 V / rated value
- 85kA
- Operational short-circuit current breaking capacity (Ics) / at 690 V / rated value
- 19
- Product variations
- Advancedapplications
- Protection class IP
- IP40
- Protection class IP / on the front
- IP40
- Reference code / acc. to DIN EN 81346-2
- Q
- Setting range / Overload function L / I**4tI**2t can be changed over
- No
- Setting range / Overload function L / IR can be switched on
- No
- Setting range / Overload function L / Setting current IR / Factor
- xIn
- Short-circuit current making capacity (Icm) / at 240 V / rated value
- 242kA
- Short-circuit current making capacity (Icm) / at 415 V / rated value
- 187kA
- Width
- 280
Do you have a question about 3VA6580-6JP42-0AA0?
Request a quote