Product overview

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM (CLASS H) BREAKING CAPACITY. 800A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU550 TRIP UNIT LCD LSI. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D) IN 11.1 x 12.5 x 5.8.

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM (CLASS H) BREAKING CAPACITY. 800A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU550 TRIP UNIT LCD LSI. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D) IN 11.1 x 12.5 x 5.8.

Manufacturer highlights

Additional manufacturer notes

Short name
S-A
Feed description
S-A 3VA6580-6JP42-0AA0 BRKR 3VA65 4
Invoice description
BRKR 3VA65 4P 800A 65KA ETU5-LSI NUT

Specifications

UPC
804766979941
Number Of Poles
4
Adjustable delay time / of S-trip / with I2t characteristic / Full-scale value
0.50s
Adjustable delay time / of S-trip / with I2t characteristic / initial value
0.05s
Adjustable delay time / of S-trip / with standard characteristic / Full-scale value
0.50s
Adjustable delay time / of S-trip / with standard characteristic / initial value
0.05s
Adjustable pick-up value current / of instantaneous short-circuit trip unit / Full-scale value
8000
Adjustable pick-up value current / of instantaneous short-circuit trip unit / initial value
1200
Adjustable pick-up value current / of the current-dependent overload release / Full-scale value
800
Adjustable pick-up value current / of the current-dependent overload release / initial value
320
Adjustable pick-up value current / of the short-time delayed short-circuit release / Full-scale value
8000.00A
Adjustable pick-up value current / of the short-time delayed short-circuit release / initial value
480.00A
Ambient temperature / during operation / maximum
70
Ambient temperature / during operation / minimum
-25
Ambient temperature / during storage / maximum
80
Electrical endurance (switching cycles) / at AC-1 / at 380/415 V / at 50/60 Hz
5800
Electrical endurance (switching cycles) / at AC-1 / at 690 V / at 50/60 Hz
4000
Height
328
Maximum short-circuit current breaking capacity (Icu) / at 240 V / rated value
110
Maximum short-circuit current breaking capacity (Icu) / at 415 V / rated value
85
Mechanical service life (switching cycles) / typical
10000
Mounting type
fixedmounting
Number Of Poles
4
Operational short-circuit current breaking capacity (Ics) / at 240 V / rated value
110kA
Operational short-circuit current breaking capacity (Ics) / at 415 V / rated value
85kA
Operational short-circuit current breaking capacity (Ics) / at 690 V / rated value
19
Product variations
Advancedapplications
Protection class IP
IP40
Protection class IP / on the front
IP40
Reference code / acc. to DIN EN 81346-2
Q
Setting range / Overload function L / I**4tI**2t can be changed over
No
Setting range / Overload function L / IR can be switched on
No
Setting range / Overload function L / Setting current IR / Factor
xIn
Short-circuit current making capacity (Icm) / at 240 V / rated value
242kA
Short-circuit current making capacity (Icm) / at 415 V / rated value
187kA
Width
280