Call Us Today: (800) 462-7733
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM (CLASS H) BREAKING CAPACITY. 800A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU860 TRIP UNIT LCD LSIG WITH METERING. SPECIAL FEATURESCONNECTION WITH LUG TERMINAL / NUT KEEPER. 100 PERCENT RATED. DIMENSIONS (W x Hx D) IN 11.1 x 12.5 x 5.8.

Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more information.

3VA6580-6KQ42-2AA0

$20,734.88 / EA

manufacturer discounts
learn about discounts

  • $18,589.90 for $1,500.00+
  • $17,874.90 for $2,500.00+
  • $17,159.90 for $3,500.00+
Available to order

Local stock: 0
Lead time: over 7 working days

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM (CLASS H) BREAKING CAPACITY. 800A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU860 TRIP UNIT LCD LSIG WITH METERING. SPECIAL FEATURESCONNECTION WITH LUG TERMINAL / NUT KEEPER. 100 PERCENT RATED. DIMENSIONS (W x Hx D) IN 11.1 x 12.5 x 5.8.

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM (CLASS H) BREAKING CAPACITY. 800A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU860 TRIP UNIT LCD LSIG WITH METERING. SPECIAL FEATURESCONNECTION WITH LUG TERMINAL / NUT KEEPER. 100 PERCENT RATED. DIMENSIONS (W x Hx D) IN 11.1 x 12.5 x 5.8.

150

UPC
804766981364
Number Of Poles:
4
Ambient temperature / during storage / minimum:
-40
Height:
328
N-Leiter Schutz / einstellbar:
Yes
N-Leiterschutz N / Einstellparameter Strom InN / Einheit der Werteliste:
Unit
N-Leiterschutz N / Einstellparameter Strom InN / Format der Werteliste:
xIn
N-Leiterschutz N / Einstellparameter Strom InN / Werteliste:
0.2-1;0
N-leiter-schutz / Ein-/Ausschaltbar:
Yes
Number Of Poles:
4
Product function / Ground fault protection:
Yes
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Factor:
s
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Factor of grading:
Settingtable
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Grading:
0.05-0.8;0.01
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (on) / Factor:
s
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (on) / Factor of grading:
Settingtable
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (on) / Grading:
0.05-0.8;0.01
Setting range / Earth fault function G / Ig-function can be switched on/off:
Yes
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Factor:
xIn
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Factor of grading:
Unit
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Grading:
0.2-1;0
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / Factor:
xIn
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / Factor of grading:
Unit
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / Grading:
0.2-1;0
Setting range / Short-circuit function, instantaneous I / Setting current Ii / Factor:
xIn
Setting range / Short-circuit function, instantaneous I / Setting current Ii / Factor of grading:
Unit
Setting range / Short-circuit function, instantaneous I / Setting current Ii / Grading:
1.5-10;0
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (off) / Factor:
s
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (off) / Grading:
0.05-0.5;0.01
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Factor:
s
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Grading:
0.05-0.5;0.01
Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / Factor:
xIn
Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / Factor of grading:
Unit
Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / Grading:
0.6-10;0
Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / max:
10
Setting range / ground fault function G / lg function selectable:
Yes
Width:
280
i-trip unit / can be switched ON/OFF:
No
version / Overcurrent release / Adjustability / Short-circuit function, instantaneous I:
Yes

Recently Viewed

  • placeholder image

    3VA6580-6KQ42-2AA0

    SIEMENS INDUSTRY, INC.
    SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM (CLASS H) BREAKING CAPACITY. 800A 4-POLE (22...
    See more details
  • placeholder image

    GM1321S-L9-40K-VG

    DABMAR LIGHTING INC.
    Unfortunately, we do not have a description available for GM1321S-L9-40K-VG. Please call (800) 462...
    See more details
  • placeholder image

    D3400-L20-30K-BZ-FR

    DABMAR LIGHTING INC.
    Unfortunately, we do not have a description available for D3400-L20-30K-BZ-FR. Please call (800) 4...
    See more details
  • placeholder image

    302040-SKT-14-77

    HUBBARDTON FORGE
    Unfortunately, we do not have a description available for 302040-SKT-14-77. Please call (800) 462-...
    See more details
  • placeholder image

    750116-89-82-LB-VA0717

    HUBBARDTON FORGE
    Unfortunately, we do not have a description available for 750116-89-82-LB-VA0717. Please call (800...
    See more details

ADDED TO CART