$16,315.11 / EA
manufacturer discounts
learn about discounts
- $14,627.34 for $1,500.00+
- $14,064.75 for $2,500.00+
- $13,502.16 for $3,500.00+
Local stock: 0
Lead time:
over 7 working days
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM HIGH (CLASS C) BREAKING CAPACITY. 800A 4-POLE (35KAICAT 600V) (100KAIC AT 480V). ETU350 TRIP UNIT LSI. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D) IN 11.1 x 12.5 x 5.8.
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA65 FRAME WITH MEDIUM HIGH (CLASS C) BREAKING CAPACITY. 800A 4-POLE (35KAICAT 600V) (100KAIC AT 480V). ETU350 TRIP UNIT LSI. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D) IN 11.1 x 12.5 x 5.8.
150
- UPC
- 804766980152
- Number Of Poles:
- 4
- Ambient temperature / during storage / minimum:
- -40
- Height:
- 328
- N-Leiter Schutz / einstellbar:
- Yes
- N-Leiterschutz N / Einstellparameter Strom InN / Einheit der Werteliste:
- Unit
- N-Leiterschutz N / Einstellparameter Strom InN / Format der Werteliste:
- xIn
- N-Leiterschutz N / Einstellparameter Strom InN / Werteliste:
- 0.5;1
- N-leiter-schutz / Ein-/Ausschaltbar:
- Yes
- Number Of Poles:
- 4
- Product function / Ground fault protection:
- No
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Factor:
- s
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Factor of grading:
- Unit
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Grading:
- 0.1;0.3
- Setting range / Earth fault function G / Ig-function can be switched on/off:
- Yes
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Factor:
- xIn
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Factor of grading:
- Unit
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Grading:
- 0.2;0.4;0.6;0.8;1
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / max:
- 1
- Setting range / Overload function L / Delay time tR / I**2t characteristic curve / max:
- 17
- Setting range / Overload function L / Setting current IR / max:
- 1
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / Factor:
- xIn
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / Factor of grading:
- Unit
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / Grading:
- 10
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / max:
- 10
- Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Factor:
- s
- Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Factor of grading:
- Unit
- Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Grading:
- 0.04;0.08;0.15;0.22;0.3;0.4
- Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / Factor:
- xIr
- Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / Factor of grading:
- Unit
- Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / Grading:
- 1.5;2;2.5;3;3.5;4;5;6;8;10
- Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / max:
- 10
- Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / can be switched on/off:
- No
- Setting range / Short-circuit function, short-time delay / can be switched on/off:
- No
- Setting range / ground fault function G / lg function selectable:
- No
- Trip class / of the L-trip / with I2t characteristic / Full-scale value:
- 17
- Width:
- 280
- i-trip unit / can be switched ON/OFF:
- No
- version / Overcurrent release / Adjustability / Short-circuit function, instantaneous I:
- Yes