No image currently available
Videos & documents
Documents
3VA6610-6JP42-0AA0
SKU: 3VA6610-6JP42-0AA0
MPN: 3VA6610-6JP42-0AA0
Key specs
View all- Number Of Poles
- 4
Description
Product overview
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA66 FRAME WITH MEDIUM (CLASS H) BREAKING CAPACITY. 1000A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU550 TRIP UNIT LCD LSI. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D) IN 11.1 x 12.5 x 5.8.
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA66 FRAME WITH MEDIUM (CLASS H) BREAKING CAPACITY. 1000A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU550 TRIP UNIT LCD LSI. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D) IN 11.1 x 12.5 x 5.8.
Manufacturer highlights
Additional manufacturer notes
- Short name
- S-A
- Feed description
- S-A 3VA6610-6JP42-0AA0 BRKR 3VA66 4
- Invoice description
- BRKR 3VA66 4P 1000A 65KA ETU5-LSI NUT
Specifications
- UPC
- 804766980558
- Number Of Poles
- 4
- Adjustable delay time / of S-trip / with I2t characteristic / Full-scale value
- 0.50s
- Adjustable delay time / of S-trip / with I2t characteristic / initial value
- 0.05s
- Adjustable delay time / of S-trip / with standard characteristic / Full-scale value
- 0.50s
- Adjustable delay time / of S-trip / with standard characteristic / initial value
- 0.05s
- Adjustable pick-up value current / of instantaneous short-circuit trip unit / Full-scale value
- 10000
- Adjustable pick-up value current / of instantaneous short-circuit trip unit / initial value
- 1500
- Adjustable pick-up value current / of the current-dependent overload release / Full-scale value
- 1000
- Adjustable pick-up value current / of the current-dependent overload release / initial value
- 400
- Adjustable pick-up value current / of the short-time delayed short-circuit release / Full-scale value
- 10000.00A
- Adjustable pick-up value current / of the short-time delayed short-circuit release / initial value
- 600.00A
- Ambient temperature / during storage / maximum
- 80
- Continuous current / rated value
- 1000
- Continuous current / rated value / maximum
- 1000.0A
- Ground fault monitoring version
- Without
- Height
- 328
- Insulation voltage / rated value
- 600
- Maximum short-circuit current breaking capacity (Icu) / at 240 V / rated value
- 110
- Maximum short-circuit current breaking capacity (Icu) / at 415 V / rated value
- 85
- Mounting type
- fixedmounting
- Number Of Poles
- 4
- Operating voltage / at AC / at 50/60 Hz / rated value
- 600
- Operational short-circuit current breaking capacity (Ics) / at 240 V / rated value
- 110kA
- Operational short-circuit current breaking capacity (Ics) / at 415 V / rated value
- 85kA
- Operational short-circuit current breaking capacity (Ics) / at 690 V / rated value
- 19
- Overcurrent release / Protective functions
- LSIN
- Power loss [W] / for rated value of the current / at AC / in hot operating state / per pole
- 110
- Product feature / for neutral conductors / upgradeable/retrofittable / Short-circuit and overload proof
- No
- Product function / Intrinsic device protection
- Yes
- Product variations
- Advancedapplications
- Protection class IP
- IP40
- Protection class IP / on the front
- IP40
- Setting range / Overload function L / IR can be switched on
- No
- Switching capacity class of the circuit breaker
- H
- Width
- 280
Do you have a question about 3VA6610-6JP42-0AA0?
Request a quote