Call Us Today: (800) 462-7733
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA66 FRAME WITH MEDIUM (CLASS H) BREAKING CAPACITY. 1000A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU856 TRIP UNIT LCD LSI GROUNG ALARM WITH METERING. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D)IN 11.1 x 12.5 x 5.8.

Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more information.

3VA6610-6KT42-0AA0

$24,475.01 / EA

manufacturer discounts
learn about discounts

  • $21,943.12 for $1,500.00+
  • $21,099.15 for $2,500.00+
  • $20,255.18 for $3,500.00+
Available to order

Local stock: 0
Lead time: over 7 working days

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA66 FRAME WITH MEDIUM (CLASS H) BREAKING CAPACITY. 1000A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU856 TRIP UNIT LCD LSI GROUNG ALARM WITH METERING. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D)IN 11.1 x 12.5 x 5.8.

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA66 FRAME WITH MEDIUM (CLASS H) BREAKING CAPACITY. 1000A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU856 TRIP UNIT LCD LSI GROUNG ALARM WITH METERING. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D)IN 11.1 x 12.5 x 5.8.

150

UPC
804766980657
Number Of Poles:
4
Height:
328
Number Of Poles:
4
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Factor:
s
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Factor of grading:
Settingtable
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Grading:
0.05-0.8;0.01
Setting range / Earth fault function G / Ig-function can be switched on/off:
Yes
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Factor:
xIn
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Factor of grading:
Unit
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Grading:
0.2-1;0
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / Factor:
xIn
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / Factor of grading:
Unit
Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Factor:
s
Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Factor of grading:
Settingtable
Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Grading:
0.5-25;0.1
Setting range / Short-circuit function, instantaneous I / Setting current Ii / Factor:
xIn
Setting range / Short-circuit function, instantaneous I / Setting current Ii / Factor of grading:
Unit
Setting range / Short-circuit function, instantaneous I / Setting current Ii / Grading:
1.5-10;0
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (off) / Factor:
s
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (off) / Factor of grading:
Settingtable
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (off) / Grading:
0.05-0.5;0.01
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Factor:
s
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Factor of grading:
Settingtable
Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Grading:
0.05-0.5;0.01
Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / Factor:
xIn
Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / Factor of grading:
Unit
Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / Grading:
0.6-10;0
Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / Factor:
xIn
Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / Factor of grading:
Unit
Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / Grading:
0.6-10;0
Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / can be switched on/off:
Yes
Setting range / ground fault function G / lg function selectable:
Yes
Total disconnection time / for G-tripping / with standard characteristic / Full-scale value:
0.80s
Trip class / of the L-trip / with I2t characteristic / Full-scale value:
25
Trip class / of the L-trip / with I2t characteristic / initial value:
0.5
Width:
280
i-trip unit / can be switched ON/OFF:
No
version / Overcurrent release / Adjustability / Short-circuit function, instantaneous I:
Yes

Recently Viewed

  • placeholder image

    3VA6610-6KT42-0AA0

    SIEMENS INDUSTRY, INC.
    SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA66 FRAME WITH MEDIUM (CLASS H) BREAKING CAPACITY. 1000A 4-POLE (2...
    See more details
  • placeholder image

    207833-SKT-89-GG0106

    HUBBARDTON FORGE
    Unfortunately, we do not have a description available for 207833-SKT-89-GG0106. Please call (800)...
    See more details
  • placeholder image

    GM136S-L9-40K-W-FR

    DABMAR LIGHTING INC.
    Unfortunately, we do not have a description available for GM136S-L9-40K-W-FR. Please call (800) 46...
    See more details
  • placeholder image

    D5500-L12-30K-10T-B

    DABMAR LIGHTING INC.
    Unfortunately, we do not have a description available for D5500-L12-30K-10T-B. Please call (800) 4...
    See more details
  • placeholder image

    LPT54/850/E39/G2-74

    TOPAZ LIGHTING CORP.
    POST TOP RETRO FIT LED LIGHT
    See more details

ADDED TO CART