SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA66 FRAME WITH MEDIUM (CLASS H) BREAKING CAPACITY. 1000A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU856 TRIP UNIT LCD LSI GROUNG ALARM WITH METERING. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D)IN 11.1 x 12.5 x 5.8.
SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA66 FRAME WITH MEDIUM (CLASS H) BREAKING CAPACITY. 1000A 4-POLE (22KAIC AT 600V) (65KAIC AT 480V). ETU856 TRIP UNIT LCD LSI GROUNG ALARM WITH METERING. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D)IN 11.1 x 12.5 x 5.8.
150
- UPC
- 804766980657
- Number Of Poles:
- 4
- Height:
- 328
- Number Of Poles:
- 4
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Factor:
- s
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Factor of grading:
- Settingtable
- Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / Grading:
- 0.05-0.8;0.01
- Setting range / Earth fault function G / Ig-function can be switched on/off:
- Yes
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Factor:
- xIn
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Factor of grading:
- Unit
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / Grading:
- 0.2-1;0
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / Factor:
- xIn
- Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / Factor of grading:
- Unit
- Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Factor:
- s
- Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Factor of grading:
- Settingtable
- Setting range / Overload function L / Delay time tR / I**2t characteristic curve / Grading:
- 0.5-25;0.1
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / Factor:
- xIn
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / Factor of grading:
- Unit
- Setting range / Short-circuit function, instantaneous I / Setting current Ii / Grading:
- 1.5-10;0
- Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (off) / Factor:
- s
- Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (off) / Factor of grading:
- Settingtable
- Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (off) / Grading:
- 0.05-0.5;0.01
- Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Factor:
- s
- Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Factor of grading:
- Settingtable
- Setting range / Short-circuit function, short-time delay / Delay time tsd / I**2t (on) / Grading:
- 0.05-0.5;0.01
- Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / Factor:
- xIn
- Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / Factor of grading:
- Unit
- Setting range / Short-circuit function, short-time delay / Setting current IS / I**2t (on) / Grading:
- 0.6-10;0
- Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / Factor:
- xIn
- Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / Factor of grading:
- Unit
- Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / Grading:
- 0.6-10;0
- Setting range / Short-circuit function, short-time delay / Setting current IS / StandardI**2t / can be switched on/off:
- Yes
- Setting range / ground fault function G / lg function selectable:
- Yes
- Total disconnection time / for G-tripping / with standard characteristic / Full-scale value:
- 0.80s
- Trip class / of the L-trip / with I2t characteristic / Full-scale value:
- 25
- Trip class / of the L-trip / with I2t characteristic / initial value:
- 0.5
- Width:
- 280
- i-trip unit / can be switched ON/OFF:
- No
- version / Overcurrent release / Adjustability / Short-circuit function, instantaneous I:
- Yes