Call Us Today: (800) 462-7733

3VA6610-7JT42-0AA0

SKU: 3VA6610-7JT42-0AA0

MPN: 3VA6610-7JT42-0AA0

Key specs

View all
Number Of Poles
4

Description

Product overview

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA66 FRAME WITH MEDIUM HIGH (CLASS C) BREAKING CAPACITY. 1000A 4-POLE (35KAIC AT 600V) (100KAIC AT 480V). ETU556 TRIP UNIT LCD LSI GROUND ALARM. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D) IN 11.1x 12.5 x 5.8.

SIEMENS LOW VOLTAGE 3VA UL MOLDED CASE CIRCUIT BREAKER WITH ELECTRONIC TRIP UNIT. 3VA66 FRAME WITH MEDIUM HIGH (CLASS C) BREAKING CAPACITY. 1000A 4-POLE (35KAIC AT 600V) (100KAIC AT 480V). ETU556 TRIP UNIT LCD LSI GROUND ALARM. SPECIAL FEATURES CONNECTION WITH LUG TERMINAL / NUT KEEPER.. DIMENSIONS (W x H x D) IN 11.1x 12.5 x 5.8.

Manufacturer highlights

Additional manufacturer notes

Short name
S-A
Feed description
S-A 3VA6610-7JT42-0AA0 BRKR 3VA66 4
Invoice description
BRKR 3VA66 4P 1000A 100KA ETU5-LSIA NUT

Specifications

UPC
804766980770
Number Of Poles
4
Continuous current / rated value
1000
Continuous current / rated value / maximum
1000.0A
Depth
120
Design of the operating mechanism
togglehandle
Design of the overcurrent release
ETU556
Design of the product
Systemprotection
Ground fault monitoring version
Without
Height
328
Insulation voltage / rated value
600
Number Of Poles
4
Operating voltage / at AC / at 50/60 Hz / rated value
600
Overcurrent release / Protective functions
LSIN
Power loss [W] / for rated value of the current / at AC / in hot operating state / per pole
110
Power loss [W] / maximum
330
Product component / adjusting knob
No
Product component / display
Yes
Product designation
Molded-casecircuitbreaker
Product designation / according to UL file
CMNAE
Product feature / for neutral conductors / upgradeable/retrofittable / Short-circuit and overload proof
No
Product function / Intrinsic device protection
Yes
Product function / communication function
Yes
Product function / other measurement function
Yes
Protective function of the overcurrent release
LSI
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / max
0.8
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (off) / minimum
0.05
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (on) / max
0.8
Setting range / Earth fault function G / Delay time tG, tripped / I**2t (on) / minimum
0.05
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (off) / minimum
0.2
Setting range / Earth fault function G / Setting current IG, tripped / I**2t (on) / minimum
0.2
Setting range / Short-circuit function, instantaneous I / Setting current Ii / minimum
1.5
Short-circuit current making capacity (Icm) / at 690 V / rated value
74.00kA
Simaris relevant
-
Suitability for use
systemprotection
Type of the driving mechanism / motor drive
No
Width
280
circuit-breaker / Design
3VA6
product brand name
SENTRON

Do you have a question about 3VA6610-7JT42-0AA0?

Request a quote

Videos & documents