ISOLATING TRANSFORMER 61558-2-6, EN61131-2 SAFETY INSTALLATION SCREW EN TERMINALS SCREW CONNECTION /B W(%) 5 IP00 TYPE OF PROTECTION CL. I TA/ISOKL 60 GR./SHIELD WNG. II0 /0 F(HZ) 50...60 VECTOR DC) 24 ISEC(A DC) 15 UPRI(V) 400-230+/-15 USEC(V PN(KW) 0,36 POWER SUPPLY PHASES 1
ISOLATING TRANSFORMER 61558-2-6, EN61131-2 SAFETY INSTALLATION SCREW EN TERMINALS SCREW CONNECTION /B W(%) 5 IP00 TYPE OF PROTECTION CL. I TA/ISOKL 60 GR./SHIELD WNG. II0 /0 F(HZ) 50...60 VECTOR DC) 24 ISEC(A DC) 15 UPRI(V) 400-230+/-15 USEC(V PN(KW) 0,36 POWER SUPPLY PHASES 1
150
- UPC
- 754554885728
- UNSPSC
- 39121026
- Country of Origin
- CZ
- Ambient temperature / rated value:
- 60 °C
- Certificate of suitability:
- CE
- Construction form of the iron core:
- EI150/48
- Depth:
- 140 m
- Electrical input frequency / maximum:
- 60 Hz
- Electrical input frequency / minimum:
- 50 Hz
- Height:
- 200 m
- Input current / _1 / rated value:
- 1.55 A
- Input current / _2 / rated value:
- 1.6 A
- Input current / _3 / rated value:
- 1.65 A
- Input current / _4 / rated value:
- 2.7 A
- Input current / _5 / rated value:
- 2.8 A
- Input current / _6 / rated value:
- 2.9 A
- Input voltage / _1 / rated value:
- 415 V
- Input voltage / _2 / rated value:
- 400 V
- Input voltage / _3 / rated value:
- 385 V
- Input voltage / _4 / rated value:
- 245 V
- Input voltage / _5 / rated value:
- 230 V
- Input voltage / _6 / rated value:
- 215 V
- Input voltage / maximum:
- 439.90 V
- Input voltage / minimum:
- 193.5 V
- Operating resource protection class:
- I
- Output current / _1 / rated value:
- 15 A
- Output current / at DC / at 40 °C / rated value / maximum:
- 18 A
- Output current / at DC / at 60 °C / rated value / maximum:
- 15 A
- Output voltage / _1 / rated value:
- 24 V
- Output voltage / of the measurement signal / at analog output / at DC / maximum:
- 28.8 V
- Output voltage / of the measurement signal / at analog output / at DC / minimum:
- 20.4 V
- Phase number / of the inputs:
- 1
- Protection class IP:
- IP00
- Relative residual ripple / of the output voltage 1 / for main current circuit / maximum:
- 5 %
- Thermal class / acc. to IEC 60085:
- B
- Type of current / _1 / at output:
- DC
- Type of current / of the inputs:
- AC
- Vector group:
- Ii0
- Width:
- 150 m