Image colors may not be accurate.
Please see details, or call (800) 462-7733 for more
information.
$38,077.42 / EA
manufacturer discounts
learn about discounts
- $34,138.38 for $1,500.00+
- $32,825.36 for $2,500.00+
- $31,512.35 for $3,500.00+
In stock (0)
Lead time: over 7 days
may be longer on small orders
Enclosed soft starter, Controller 3RW40766BB34, H2 Std. duty current rating 385A, Control voltage 115 AC, Non-combination type, Enclosure NEMA type 12, Dust/drip proof for indoors
Enclosed soft starter, Controller 3RW40766BB34, H2 Std. duty current rating 385A, Control voltage 115 AC, Non-combination type, Enclosure NEMA type 12, Dust/drip proof for indoors
150
- UPC
- 783087823716
- Degree of protection NEMA rating / of the enclosure:
- NEMAType12
- Design of the fuse link / for short-circuit protection of the main circuit / required:
- 10kA@600V(ClassHorK);100kA@600V(ClassRorJ)
- Design of the short-circuit trip:
- Thermalmagneticcircuitbreaker
- Material / of the conductor / for auxiliary and control contacts:
- CU
- Maximum short-circuit current breaking capacity (Icu) / at 480 V / acc. to NEMA / Rated value:
- 100 kA
- Number of parameter sets:
- 1
- Operating range factor supply voltage rated value / maximum:
- 1.1
- Operating range factor supply voltage rated value / minimum:
- 0.85
- Operating voltage / at AC-3 / Rated value / maximum:
- 460 V
- Product component / engineering software (Soft Starter ES):
- No
- Product extension / optional / human machine interface module:
- No
- Product function / DC braking:
- No
- Product function / Disconnector functionality:
- No
- Product function / Operating measured value display:
- No
- Product function / breakaway pulse:
- No
- Product function / combined braking:
- No
- Product function / error logbook:
- No
- Product function / event list:
- No
- Product function / inside-delta circuit:
- No
- Product function / motor heating:
- No
- Product function / overload protection:
- Yes
- Product function / ramp-up (soft starting)/ramp-down (soft stop):
- Yes
- Product function / slave pointer function:
- No
- Product function / trace function:
- No
- Protection against electrical shock:
- NAforenclosedproducts
- Temperature / of the conductor / for line-side / maximum permissible:
- 75 °C
- Temperature / of the conductor / for auxiliary and control contacts / maximum permissible:
- 75 °C
- Temperature / of the conductor / for load-side outgoing feeder / maximum permissible:
- 75 °C
- Tightening torque / for line-side / maximum:
- 195 lbf.in
- Tightening torque / for line-side / minimum:
- 180 lbf.in
- Tightening torque / for load-side outgoing feeder / maximum:
- 195 lbf.in
- Tightening torque [lbf·in] / for auxiliary and control contacts / with screw-type terminals / maximum:
- 10 lbf.in
- Tightening torque [lbf·in] / for auxiliary and control contacts / with screw-type terminals / minimum:
- 7 lbf.in
- Trip CLASS:
- Class5/15/20
- Type of electrical connection / for auxiliary and control current circuit:
- screw-typeterminals
- Wire length / between motor starter and motor / maximum:
- 300 m